ArticleBiomedical optics express2024
Digital calibration method to enable depth-resolved all-fiber polarization sensitive optical coherence tomography with an arbitrary input polarization state.
Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- High-speed, wide-field, fiber-based PS-OCT system with real-time surface Stokes feedback for circular input polarization.Biomedical optics express · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We present a fully integrated depth-resolved all fiber-based polarization sensitive optical coherence tomography (PSOCT). In contrast to conventional fiber-based PSOCT systems, which require additional modules to generate two or more input polarization states, or a pre-adjustment procedure to generate a circularly polarized light, the proposed all-fiber PSOCT system can provide depth-resolved birefringent imaging using an arbitrary single input polarization state. Utilizing the discrete differential geometry (DDG)-based polarization state tracing (PST) method, combined with several geometric rotations and transformations in the Stokes space, two problems induced by the optical fibers can be mitigated: 1) The change in the polarization state introduced by the optical fibers can be effectively compensated using a calibration target at the distal end of the probe, and the computations of the local axis orientation and local phase retardation can be achieved with a single arbitrary input polarization state, eliminating the need for a pre-defined input polarization state, allowing a flexible system design and user-friendly experimental procedure; 2) The polarization mode dispersion (PMD) induced by the optical fibers can be compensated digitally without the requirement of additional input polarization states, providing an accurate PSOCT imaging result. To demonstrate the performance of the proposed method, the depth resolved PSOCT results of a plastic phantom and
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.