Evidence map›Paper›PMID 38867951›Full record

ArticleHeliyon2024

Day-ahead resilience-economic energy management and feeder reconfiguration of a CCHP-based microgrid, considering flexibility of supply.

Jaber Moosanezhad, Ali Basem, Farshad Khalafian, Alhussein G Alkhayer, Ameer H Al-Rubaye, Mohsen Khosravi, Hossein Azarinfar

RetractedAbstract readRetracted Publication
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Jaber MoosanezhadDepartment of Management, Economics, and Accounting, Payame Noor University (PNU), Tehran, Iran.
Ali BasemFaculty of Engineering, Warith Al-Anbiyaa University, Karbala, 56001, Iraq.
Farshad KhalafianDepartment of Electrical Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran.
Alhussein G AlkhayerDepartment of Electrical Engineering Techniques, Al-Amarah University College, Maysan, Iraq.
Ameer H Al-RubayeDepartment of Petroleum Engineering, Al-Kitab University, Altun Kupri, Iraq.
Mohsen KhosraviFaculty of Computer and Electrical Engineering, University of Gonabad, St. Ghafari, Gonabad, Iran.
Hossein AzarinfarFaculty of Computer and Electrical Engineering, University of Gonabad, St. Ghafari, Gonabad, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many challenges have emerged due to the intense integration of renewables in the distribution system and the associated uncertainties in power generation. Consequently, local management strategies are developed at the distribution level, leading to the emergence of concepts such as microgrids. Microgrids include a variety of heating, cooling, and electrical resources and loads, and the operators' aim is to minimize operation and outage costs. Since significant distribution system outages are typically caused by events such as earthquakes, floods, and hurricanes, microgrid operators are compelled to improve resilience to ensure uninterrupted service during such conditions. A mixed-integer linear programming model is designed in this paper to optimize the energy management and structural configuration of microgrids. This optimization aims to enhance resilience cost, minimizing operation and capital costs as well as power loss and pollution. To achieve these goals, several tools are implemented including reconfiguration, storages, combined cooling, heat and power units, wind turbines, photovoltaic panels, as well as capacitors. Four case studies are defined to prove the developed model efficiency. The first case study focuses on energy management in the microgrid for operation cost minimization. The second case study emphasizes the improvement of resilience alongside energy management, aiming at minimizing costs and enhance resilience. In the third case, the microgrid's reconfiguration capability is also added to the second case. Therefore, this case aims to optimize both energy and structural management within the microgrid to simultaneously enhance resilience and minimize operational costs. Finally, in the fourth case, the problem is studied in a multi-objective approach. By comparing the results, the resilience impact on the operation of microgrids is elucidated. By considering the resilience concept in microgrid operation and based on the results of case 2, it is found that the operating costs are increased by an average of 10.38 %. However, because of reducing resilience costs by an average of 13.91 %, the total cost is reduced by an average of 5.93 % in case 2 compared to case 1. Furthermore, when comparing cases 2 and 3, the reconfiguration effect can be determined. It can be observed that the operating costs are decreased by an average of 4.5 %. Moreover, the resilience cost is decreased by an average of 1.61 %, resulting in an overall reduction of the total objective function by an average of 2.43 % in case 3 compared to case 2.

Indexed as

Combined cooling heat and power unitEnergy managementMicrogridsReconfigurationResilienceStructure management

Identifiers

PMID38867951
PMCPMC11167308

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.