Evidence map›Paper›PMID 38894192›Full record

ArticleSensors (Basel, Switzerland)2024

Influence of Front-End Electronics on Metrological Performance of QCM Systems.

Ada Fort, Elia Landi, Riccardo Moretti, Marco Mugnaini, Consolatina Liguori, Vincenzo Paciello, Salvatore Dello Iacono

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ada FortDepartment of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy.ORCID 0000-0003-0916-1516
Elia LandiDepartment of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy.
Riccardo MorettiDepartment of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy.ORCID 0000-0002-1691-3846
Marco MugnainiDepartment of Information Engineering and Mathematics, University of Siena, 53100 Siena, Italy.
Consolatina LiguoriDepartment of Industrial Engineering, University of Salerno, 84084 Salerno, Italy.ORCID 0000-0003-3254-2069
Vincenzo PacielloDepartment of Industrial Engineering, University of Salerno, 84084 Salerno, Italy.ORCID 0000-0002-9284-1741
Salvatore Dello IaconoDepartment of Information Engineering, University of Brescia, 25123 Brescia, Italy.ORCID 0000-0002-3749-0360

Funding

Ministero dell'Università e della Ricerca, Italy B83C22003920001
6 · The paper itself

Abstract

Quartz Crystal Microbalances (QCMs) are versatile sensors employed in various fields, from environmental monitoring to biomedical applications, owing mainly to their very high sensitivity. However, the assessment of their metrological performance, including the impact of conditioning circuits, digital processing algorithms, and working conditions, is a complex and novel area of study. The purpose of this work is to investigate and understand the measurement errors associated with different QCM measurement techniques, specifically focusing on the influence of conditioning electronic circuits. Through a tailored and novel experimental setup, two measurement architectures-a Quartz Crystal Microbalance with dissipation monitoring (QCM-D) system and an oscillator-based QCM-R system-were compared under the same mechanical load conditions. Through rigorous experimentation and signal processing techniques, the study elucidated the complexities of accurately assessing QCM parameters, especially in liquid environments and under large mechanical loads. The comparison between the two different techniques allows for highlighting the critical aspects of the measurement techniques. The experimental results were discussed and interpreted based on models allowing for a deep understanding of the measurement problems encountered with QCM-based measurement systems. The performance of the different techniques was derived, showing that while the QCM-D technique exhibited higher accuracy, the QCM-R technique offered greater precision with a simpler design. This research advances our understanding of QCM-based measurements, providing insights for designing robust measurement systems adaptable to diverse conditions, thus enhancing their effectiveness in various applications.

Indexed as

measurement systemsquartz crystal microbalancesignal processing

Identifiers

PMID38894192
PMCPMC11174881

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.