ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2024
High-Frequency, 2-mm-Diameter Forward-Viewing 2-D Array for 3-D Intracoronary Blood Flow Imaging.
Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Forward-Viewing Intravascular Ultrasound: Design and Fabrication for High Sensitivity 3D Imaging of Hemodynamics.IEEE transactions on bio-medical engineering · 2026Article
- Intravascular ultrasound wall shear stress imaging in stented coronary arteries with ultrafast Doppler.Scientific reports · 2026Article
- An Open Multifunctional FPGA-Based Pulser/Receiver System for Intravascular Ultrasound (IVUS) Imaging and Therapy.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Coronary artery disease (CAD) is one of the leading causes of death globally. Currently, diagnosis and intervention in CAD are typically performed via minimally invasive cardiac catheterization procedures. Using current diagnostic technology, such as angiography and fractional flow reserve (FFR), interventional cardiologists must decide which patients require intervention and which can be deferred; 10% of patients with stable CAD are incorrectly deferred using current diagnostic best practices. By developing a forward-viewing intravascular ultrasound (FV-IVUS) 2-D array capable of simultaneously evaluating morphology, hemodynamics, and plaque composition, physicians would be better able to stratify risk of major adverse cardiac events in patients with intermediate stenosis. For this application, a forward-viewing, 16-MHz 2-D array transducer was designed and fabricated. A 2-mm-diameter aperture consisting of 140 elements, with element dimensions of 98×98×70 μ m ( w×h×t ) and a nominal interelement spacing of 120 μ m, was designed for this application based on simulations. The acoustic stack for this array was developed with a designed center frequency of 16 MHz. A novel via-less interconnect was developed to enable electrical connections to fan-out from a 140-element 2-D array with 120- μ m interelement spacing. The fabricated array transducer had 96/140 functioning elements operating at a center frequency of 16 MHz with a -6-dB fractional bandwidth of 62% ± 7 %. Single-element SNR was 23 ± 3 dB, and the measured electrical crosstalk was - 33 ± 3 dB. In imaging experiments, the measured lateral resolution was 0.231 mm and the measured axial resolution was 0.244 mm at a depth of 5 mm. Finally, the transducer was used to perform 3-D B-mode imaging of a 3-mm-diameter spring and 3-D B-mode and power Doppler imaging of a tissue-mimicking phantom.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.