A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications.

Yawei Zhang, Zhuoran Jiang, You Zhang, Lei Ren

Abstract readReview
In one paragraph

Review in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yawei ZhangDepartment of Radiation Oncology, University of Florida Health Proton Therapy Institute, Jacksonville, Florida, USA.
Zhuoran JiangMedical Physics Graduate Program, Duke University, Durham, North Carolina, USA.
You ZhangDepartment of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas, USA.
Lei RenDepartment of Radiation Oncology, University of Maryland, Baltimore, Maryland, USA.

Funding

eXtended Modular ANthropomorphic (XMAN) phantom for Imaging and Treatment Optimization in Radiotherapy.R01EB032680 · NIBIB · UNIVERSITY OF MARYLAND BALTIMORE · PI REN, LEI, YANG, XIAOFENG · 2022 to 2025
$2.4M
Hybrid virtual-MRI/CBCT: A new paradigm for image guidance in liver SBRTR01EB028324 · NIBIB · UNIVERSITY OF MARYLAND BALTIMORE · PI REN, LEI, YIN, FANG-FANG · 2019 to 2022
$2.1M
NIBIB NIH HHS R01 EB028324NIBIB NIH HHS R01 EB032680NIH HHS R01EB028324NIH HHS R01EB032680
6 · The paper itself

Abstract

Cone-beam CT (CBCT) is the most commonly used onboard imaging technique for target localization in radiation therapy. Conventional 3D CBCT acquires x-ray cone-beam projections at multiple angles around the patient to reconstruct 3D images of the patient in the treatment room. However, despite its wide usage, 3D CBCT is limited in imaging disease sites affected by respiratory motions or other dynamic changes within the body, as it lacks time-resolved information. To overcome this limitation, 4D-CBCT was developed to incorporate a time dimension in the imaging to account for the patient's motion during the acquisitions. For example, respiration-correlated 4D-CBCT divides the breathing cycles into different phase bins and reconstructs 3D images for each phase bin, ultimately generating a complete set of 4D images. 4D-CBCT is valuable for localizing tumors in the thoracic and abdominal regions where the localization accuracy is affected by respiratory motions. This is especially important for hypofractionated stereotactic body radiation therapy (SBRT), which delivers much higher fractional doses in fewer fractions than conventional fractionated treatments. Nonetheless, 4D-CBCT does face certain limitations, including long scanning times, high imaging doses, and compromised image quality due to the necessity of acquiring sufficient x-ray projections for each respiratory phase. In order to address these challenges, numerous methods have been developed to achieve fast, low-dose, and high-quality 4D-CBCT. This paper aims to review the technical developments surrounding 4D-CBCT comprehensively. It will explore conventional algorithms and recent deep learning-based approaches, delving into their capabilities and limitations. Additionally, the paper will discuss the potential clinical applications of 4D-CBCT and outline a future roadmap, highlighting areas for further research and development. Through this exploration, the readers will better understand 4D-CBCT's capabilities and potential to enhance radiation therapy.

Indexed as

Cone-Beam Computed TomographyFour-Dimensional Computed TomographyHumansRadiotherapy, Image-GuidedRespiration4D‐CBCTimage reconstructionmotion managementpatient positioning

Identifiers

PMID38922912
PMCPMC11321939

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.