ArticleSensors (Basel, Switzerland)2024
Compact 3D-Printed Unit for Separation of Simple Gas Mixtures Combined with Chemiresistive Sensors.
Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Optimizing Low-Cost Gas Analysis with a 3D Printed Column and MiCS-6814 Sensor for Volatile Compound Detection.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Inexpensive chemiresistive sensors are often insufficiently selective as they are sensitive to multiple components of the gas mixture at the same time. One solution would be to insert a device in front of the sensor that separates the measured gas mixture and possibly isolates the unwanted components. This study focused on the fabrication and characterization of a compact unit, which was fabricated by 3D printing, for the separation and detection of simple gas mixtures. The capillary, the basic part of the compact unit, was 4.689 m long and had a diameter of 0.7 mm. The compact unit also contained a mixing chamber on the inlet side and a measuring chamber with a MiCS-6814 sensor on the outlet side. Mixtures of ethanol and water at different concentrations were chosen for characterization. The measured calibration curve was found to have a reliability of R