Evidence map›Paper›PMID 39010013›Full record

ArticleBMC anesthesiology2024

Evaluation of the effect of trendelenburg position duration on intracranial pressure in laparoscopic hysterectomies using ultrasonographic optic nerve sheath diameter measurements.

Hulya Guloglu, Dilek Cetinkaya, Tufan Oge, Ayten Bilir

2 registry-linked trialsAbstract read
In one paragraph

Article in BMC anesthesiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06048900 nacompletednot on this map

Evaluation of the Effect of Trendelenburg Position Time on Intracranial Pressure in Laparoscopic With Ultrasonographic Optic Nerve Sheath Diameter Measurement

TypeinterventionalSponsorDilek CetinkayaRan2021 to 2022Enrolled25ConditionsIntracranial Pressure IncreaseArmsultrasound guided optic nerve sheath diameter measurement
NCT07250178 nacompletednot on this mapstarted 2025, after this paper: background citation

Effect of Surgical Approach on Optic Nerve Sheath Diameter as a Surrogate Marker of Intracranial Pressure: A Comparison Between vNOTES and Total Laparoscopic Hysterectomy

TypeinterventionalSponsorSaglik Bilimleri Universitesi Gazi Yasargil Training and Research HospitalRan2025 to 2026Enrolled66ConditionsEndometrial Cancer, Abnormal Uterine Bleeding, Myoma, UterusArmsvNOTES, TLH
3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hulya GulogluDepartment of Anesthesiology and Reanimation, Eskisehir Osmangazi University Medical Faculty, Eskisehir, Türkiye.
Dilek CetinkayaDepartment of Anesthesiology and Reanimation, Eskisehir Osmangazi University Medical Faculty, Eskisehir, Türkiye. drdceyhan@gmail.com.
Tufan OgeDepartment of Obstetrics and Gynecology, Eskisehir Osmangazi University Medical Faculty, Eskisehir, Türkiye.
Ayten BilirDepartment of Anesthesiology and Reanimation, Eskisehir Osmangazi University Medical Faculty, Eskisehir, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring laparoscopic surgery, pneumoperitoneum and Trendelenburg positioning applied to provide better surgical vision can cause many physiological changes as well as an increase in intracranial pressure. However, it has been reported that cerebral autoregulation prevents cerebral edema by regulating this pressure increase. This study aimed to investigate whether the duration of the Trendelenburg position had an effect on the increase in intracranial pressure using ultrasonographic optic nerve sheath diameter (ONSD) measurements.

methodsThe near infrared spectrometry monitoring of patients undergoing laparoscopic hysterectomy was performed while awake (T0); at the fifth minute after intubation (T1); at the 30th minute (T2), 60th minute (T3), 75th minute (T4), and 90th minute (T5) after placement in the Trendelenburg position; and at the fifth minute after placement in the neutral position (T6).

resultsThe study included 25 patients. The measured ONSD values were as follows: T0 right/left, 4.18±0.32/4.18±0.33; T1, 4.75±0.26/4.75±0.25; T2, 5.08±0.19/5.08±0.19; T3, 5.26±0.15/5.26±0.15; T4, 5.36±0.11/5.37±0.12; T5, 5.45±0.09/5.48±0.11; and T6, 4.9±0.24/4.89±0.22 ( p < 0.05 compared with T0). ). No statistical difference was detected in all measurements in terms of MAP, HR and ETCO2 values compared to the T0 value (p > 0.05).

conclusionsIt was determined that as the Trendelenburg position duration increased, the ONSD values ​​increased. This suggests that as the duration of Trendelenburg positioning and pneumoperitoneum increases, the sustainability of the mechanisms that balance the increase in intracranial pressure becomes insufficient.

trial registrationThis study was registered at Clinical Trials.gov on 21/09/2023 (registration number NCT06048900).

Indexed as

Head-Down TiltHysterectomyIntracranial PressureLaparoscopyOptic NerveUltrasonographyAdultFemaleHumansMiddle AgedMonitoring, IntraoperativePatient PositioningProspective StudiesSpectroscopy, Near-InfraredTime FactorsCerebral oxygenationPneumoperitoneumTrendelenburg position

Identifiers

PMID39010013
PMCPMC11247807

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials