ArticleBMC ophthalmology2024

Comparison of axial length and anterior segment parameters of patients with myopia measured using 2 fourier-domain optical coherent biometry devices.

Bingqing Sun, Yuhao Ye, Jing Zhao, Xingtao Zhou, Lingling Niu

Abstract readComparative Study
In one paragraph

Article in BMC ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Observational
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bingqing Sun *Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, No. 19 Baoqing Road, Shanghai, 200031, China.
Yuhao Ye *Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, No. 19 Baoqing Road, Shanghai, 200031, China.
Jing ZhaoEye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, No. 19 Baoqing Road, Shanghai, 200031, China.
Xingtao Zhou *Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, No. 19 Baoqing Road, Shanghai, 200031, China. doctzhouxingtao@163.com.
Lingling Niu *Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, No. 19 Baoqing Road, Shanghai, 200031, China. niu-lingling@hotmail.com.

Funding

National Natural Science Foundation of China 82271119Shanghai Rising-Star Program 23QA1401000
6 · The paper itself

Abstract

backgroundThis study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700.

methodsEighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants' axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots.

resultsWith the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and - 9.989 to 13.486 μm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively.

conclusionsIn young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.

Indexed as

Axial Length, EyeBiometryMyopiaAdultAnterior Eye SegmentCorneaFemaleFourier AnalysisHumansMaleRefraction, OcularTomography, Optical CoherenceYoung AdultAxial lengthCorneal thicknessIntraocular lensLens thicknessOptical coherence tomographyWhite-to-white

Identifiers

PMID39014346
PMCPMC11253327

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.