Evidence map›Paper›PMID 39022547›Full record

ArticleBiomedical optics express2024

Fabrication of a low-cost benchtop optical imager for quantum dot microarray-based stress biomarker detection.

Anusha Kishore, Arun Mathew Varughese, Bernhard Roth, Carsten Zeilinger

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Anusha KishoreLeibniz University Hannover , Centre of Biomolecular Drug Research, Schneiderberg 38, 30167 Hannover, Germany.
Arun Mathew VarugheseLeibniz University Hannover, Hannover Centre for Optical Technologies, Nienburger Str. 17, 30167 Hannover, Germany.
Bernhard RothLeibniz University Hannover, Hannover Centre for Optical Technologies, Nienburger Str. 17, 30167 Hannover, Germany.ORCID https://orcid.org/0000-0001-9389-7125
Carsten ZeilingerLeibniz University Hannover , Centre of Biomolecular Drug Research, Schneiderberg 38, 30167 Hannover, Germany.ORCID https://orcid.org/0000-0002-6560-0977

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report on a simplified optical imager to detect the presence of a stress biomarker protein, namely the Heat shock protein 90 (Hsp90). The imager consists of two elements the optical unit and the sensor, which is a custom-made biochip. Measurement is based on the masking of the streptavidin conjugated quantum dot's (Sav-QDs) fluorescence when Hsp90 attaches to it via biotinylated antibodies (Ab). The masking effect was directly proportional to the Hsp90 concentration. The cost-efficient benchtop imager developed comprises a CMOS sensor, standard optical lenses, and a narrow bandpass filter for optically eliminating background fluorescence. This approach is promising for the realization of cheap, robust, and reliable point-of-care detection systems for various biomarker analyses.

Identifiers

PMID39022547
PMCPMC11249684

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.