ArticleIEEE transactions on medical imaging2025
Interpretable Severity Scoring of Pelvic Trauma Through Automated Fracture Detection and Bayesian Inference.
Article in IEEE transactions on medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Deep learning and hybrid architectures for atypical and complex bone fracture diagnosis: a systematic review of performance and clinical validity.Frontiers in artificial intelligence · 2026Review
- Artificial intelligence for abdominopelvic trauma imaging: trends, gaps, and future directions.Abdominal radiology (New York) · 2025Review
- An Intrinsically Explainable Approach to Detecting Vertebral Compression Fractures in CT Scans via Neurosymbolic Modeling.Proceedings of SPIE--the International Society for Optical Engineering · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Pelvic ring disruptions result from blunt injury mechanisms and are potentially lethal mainly due to associated injuries and massive pelvic hemorrhage. The severity of pelvic fractures in trauma victims is frequently assessed by grading the fracture according to the Tile AO/OTA classification in whole-body Computed Tomography (CT) scans. Due to the high volume of whole-body CT scans generated in trauma centers, the overall information content of a single whole-body CT scan and low manual CT reading speed, an automatic approach to Tile classification would provide substantial value, e.g., to prioritize the reading sequence of the trauma radiologists or enable them to focus on other major injuries in multi-trauma patients. In such a high-stakes scenario, an automated method for Tile grading should ideally be transparent such that the symbolic information provided by the method follows the same logic a radiologist or orthopedic surgeon would use to determine the fracture grade. This paper introduces an automated yet interpretable pelvic trauma decision support system to assist radiologists in fracture detection and Tile grading. To achieve interpretability despite processing high-dimensional whole-body CT images, we design a neurosymbolic algorithm that operates similarly to human interpretation of CT scans. The algorithm first detects relevant pelvic fractures on CTs with high specificity using Faster-RCNN. To generate robust fracture detections and associated detection (un)certainties, we perform test-time augmentation of the CT scans to apply fracture detection several times in a self-ensembling approach. The fracture detections are interpreted using a structural causal model based on clinical best practices to infer an initial Tile grade. We apply a Bayesian causal model to recover likely co-occurring fractures that may have been rejected initially due to the highly specific operating point of the detector, resulting in an updated list of detected fractures and corresponding final Tile grade. Our method is transparent in that it provides fracture location and types, as well as information on important counterfactuals that would invalidate the system's recommendation. Our approach achieves an AUC of 0.89/0.74 for translational and rotational instability,which is comparable to radiologist performance. Despite being designed for human-machine teaming, our approach does not compromise on performance compared to previous black-box methods.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.