Evidence map›Paper›PMID 39114486›Full record

ReviewFrontiers in neuroscience2024

Decreasing the physical gap in the neural-electrode interface and related concepts to improve cochlear implant performance.

Joseph T Vecchi, Alexander D Claussen, Marlan R Hansen

Abstract readReview
In one paragraph

Review in Frontiers in neuroscience, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Frequency Following Responses to Electric Cochlear Stimulation in an Animal Model.Journal of the Association for Research in Otolaryngology : JARO · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Joseph T VecchiDepartment of Molecular Physiology and Biophysics, Carver College of Medicine, Iowa City, IA, United States.
Alexander D ClaussenDepartment of Otolaryngology Head-Neck Surgery, Carver College of Medicine, Iowa City, IA, United States.
Marlan R HansenDepartment of Molecular Physiology and Biophysics, Carver College of Medicine, Iowa City, IA, United States.

Funding

Speech Production &LanguageP50DC000242 · NIDCD · UNIVERSITY OF IOWA · PI Bruce Jay Gantz · 1989 to 2026
$58.8M
University of Iowa Institute for Clinical and Translational ScienceUM1TR004403 · NCATS · UNIVERSITY OF IOWA · PI Marlan R Hansen, Patricia Winokur · 2023 to 2026
$16.1M
MEDICAL SCIENTIST TRAINING PROGRAMT32GM007337 · NIGMS · UNIVERSITY OF IOWA · PI GEYER, PAMELA K., LENTZ, STEVEN R · 1985 to 2020
$15.9M
Medical Scientist Training ProgramT32GM139776 · NIGMS · UNIVERSITY OF IOWA · PI Gordon F Buchanan · 2021 to 2026
$6.4M
Reduction of Intracochlear Trauma and Fibrosis Using Dual Network, Zwitterionic Hydrogel Thin Films on Cochlear Implant SurfacesR01DC012578 · NIDCD · UNIVERSITY OF IOWA · PI Allan Guymon, Marlan R Hansen · 2013 to 2026
$6.3M
Role of Macrophages on Tissue Remodeling Following Cochlear ImplantationR01DC018488 · NIDCD · UNIVERSITY OF IOWA · PI Marlan R Hansen · 2020 to 2026
$2.8M
Feature characteristics and signaling mechanisms involved in SGN neurite guidance by engineered topographical and biochemical micropatternsF31DC020371 · NIDCD · UNIVERSITY OF IOWA · PI VECCHI, JOSEPH THOMAS · 2022 to 2023
$67k
NCATS NIH HHS UM1 TR004403NIDCD NIH HHS F31 DC020371NIDCD NIH HHS P50 DC000242NIDCD NIH HHS R01 DC012578NIDCD NIH HHS R01 DC018488NIGMS NIH HHS T32 GM007337NIGMS NIH HHS T32 GM139776
6 · The paper itself

Abstract

Cochlear implants (CI) represent incredible devices that restore hearing perception for those with moderate to profound sensorineural hearing loss. However, the ability of a CI to restore complex auditory function is limited by the number of perceptually independent spectral channels provided. A major contributor to this limitation is the physical gap between the CI electrodes and the target spiral ganglion neurons (SGNs). In order for CI electrodes to stimulate SGNs more precisely, and thus better approximate natural hearing, new methodologies need to be developed to decrease this gap, (i.e., transitioning CIs from a far-field to near-field device). In this review, strategies aimed at improving the neural-electrode interface are discussed in terms of the magnitude of impact they could have and the work needed to implement them. Ongoing research suggests current clinical efforts to limit the CI-related immune response holds great potential for improving device performance. This could eradicate the dense, fibrous capsule surrounding the electrode and enhance preservation of natural cochlear architecture, including SGNs. In the long term, however, optimized future devices will likely need to induce and guide the outgrowth of the peripheral process of SGNs to be in closer proximity to the CI electrode in order to better approximate natural hearing. This research is in its infancy; it remains to be seen which strategies (surface patterning, small molecule release, hydrogel coating, etc.) will be enable this approach. Additionally, these efforts aimed at optimizing CI function will likely translate to other neural prostheses, which face similar issues.

Indexed as

biomaterialscochlear implanthearing lossneural electrodeneural prosthesesoptogeneticsregenerative medicinespiral ganglion neuron (SGN)

Identifiers

PMID39114486
PMCPMC11303154

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.