ArticleJMIR human factors2024
A Handheld Tool for the Rapid Morphological Identification of Mosquito Species (VectorCam) for Community-Based Malaria Vector Surveillance: Summative Usability Study.
Article in JMIR human factors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Integration of VectorCam, an AI-Enabled Mosquito Surveillance Tool, Into Uganda's National Malaria Elimination Program: Protocol for a Mixed Methods Hybrid Type III Implementation Study.JMIR public health and surveillance · 2026Article
- Evaluating AI-based mosquito monitoring technologies: a field study in Zhejiang Province, 2025.Frontiers in veterinary science · 2026Article
- From Bites to Bytes: Evaluating User Engagement and Mosquito Bite Exposure Patterns with the Bite Diary Smartphone Application.The American journal of tropical medicine and hygiene · 2025Article
- Towards transforming malaria vector surveillance using VectorBrain: a novel convolutional neural network for mosquito species, sex, and abdomen status identifications.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMalaria impacts nearly 250 million individuals annually. Specifically, Uganda has one of the highest burdens, with 13 million cases and nearly 20,000 deaths. Controlling the spread of malaria relies on vector surveillance, a system where collected mosquitos are analyzed for vector species' density in rural areas to plan interventions accordingly. However, this relies on trained entomologists known as vector control officers (VCOs) who identify species via microscopy. The global shortage of entomologists and this time-intensive process cause significant reporting delays. VectorCam is a low-cost artificial intelligence-based tool that identifies a mosquito's species, sex, and abdomen status with a picture and sends these results electronically from surveillance sites to decision makers, thereby deskilling the process to village health teams (VHTs).
objectiveThis study evaluates the usability of the VectorCam system among VHTs by assessing its efficiency, effectiveness, and satisfaction.
methodsThe VectorCam system has imaging hardware and a phone app designed to identify mosquito species. Two users are needed: (1) an imager to capture images of mosquitos using the app and (2) a loader to load and unload mosquitos from the hardware. Critical success tasks for both roles were identified, which VCOs used to train and certify VHTs. In the first testing phase (phase 1), a VCO and a VHT were paired to assume the role of an imager or a loader. Afterward, they swapped. In phase 2, two VHTs were paired, mimicking real use. The time taken to image each mosquito, critical errors, and System Usability Scale (SUS) scores were recorded for each participant.
resultsOverall, 14 male and 6 female VHT members aged 20 to 70 years were recruited, of which 12 (60%) participants had smartphone use experience. The average throughput values for phases 1 and 2 for the imager were 70 (SD 30.3) seconds and 56.1 (SD 22.9) seconds per mosquito, respectively, indicating a decrease in the length of time for imaging a tray of mosquitos. The loader's average throughput values for phases 1 and 2 were 50.0 and 55.7 seconds per mosquito, respectively, indicating a slight increase in time. In terms of effectiveness, the imager had 8% (6/80) critical errors and the loader had 13% (10/80) critical errors in phase 1. In phase 2, the imager (for VHT pairs) had 14% (11/80) critical errors and the loader (for VHT pairs) had 12% (19/160) critical errors. The average SUS score of the system was 70.25, indicating positive usability. A Kruskal-Wallis analysis demonstrated no significant difference in SUS (H value) scores between genders or users with and without smartphone use experience.
conclusionsVectorCam is a usable system for deskilling the in-field identification of mosquito specimens in rural Uganda. Upcoming design updates will address the concerns of users and observers.