ArticleScientific reports2024
Automatic rehabilitation exercise task assessment of stroke patients based on wearable sensors with a lightweight multichannel 1D-CNN model.
Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Robust Activity Recognition via Redundancy-Aware CNNs and Novel Pooling for Noisy Mobile Sensor Data.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Approximately 75% of stroke survivors have movement dysfunction. Rehabilitation exercises are capable of improving physical coordination. They are mostly conducted in the home environment without guidance from therapists. It is impossible to provide timely feedback on exercises without suitable devices or therapists. Human action quality assessment in the home setting is a challenging topic for current research. In this paper, a low-cost HREA system in which wearable sensors are used to collect upper limb exercise data and a multichannel 1D-CNN framework is used to automatically assess action quality. The proposed 1D-CNN model is first pretrained on the UCI-HAR dataset, and it achieves a performance of 91.96%. Then, five typical actions were selected from the Fugl-Meyer Assessment Scale for the experiment, wearable sensors were used to collect the participants' exercise data, and experienced therapists were employed to assess participants' exercise at the same time. Following the above process, a dataset was built based on the Fugl-Meyer scale. Based on the 1D-CNN model, a multichannel 1D-CNN model was built, and the model using the Naive Bayes fusion had the best performance (precision: 97.26%, recall: 97.22%, F1-score: 97.23%) on the dataset. This shows that the HREA system provides accurate and timely assessment, which can provide real-time feedback for stroke survivors' home rehabilitation.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.