ArticlePediatric radiology2024
Noncontrast free-breathing ECG-gated 3D balanced steady-state free precession in congenital heart disease and aortopathy evaluation.
Article in Pediatric radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHigh-fidelity cardiac magnetic resonance (MR) imaging plays a pivotal role in the surveillance of congenital heart disease (CHD) and aortopathy.
objectiveWe aimed to evaluate the quality and accuracy of free breathing, ECG-gated noncontrast three-dimensional (3D) balanced steady-state free precession (bSSFP) in cases of CHDs and aortopathies using contrast-enhanced 3D bSSFP as a reference. We also used one of our routinely used non-ECG-gated 2D-single-shot (SSh) bSSFP sequence as an adjunct to noncontrast 3D bSSFP. MATERIALS AND
methodsInstitutional review board approval was obtained to perform a systematic retrospective analysis of image quality and vascular measurements. Patients with CHD and aortopathy, who were undergoing clinically indicated contrast-enhanced 3D bSSFP, were prospectively identified to also undergo additional noncontrast 3D bSSFP and 2D SSh bSSFP imaging as part of a clinical quality improvement initiative aimed at reducing the use of contrast when feasible. Two readers, blinded to each other's evaluations, graded image quality on a 5-point Likert scale and performed vascular measurements in separate sessions for both 3D bSSFP images. They also reported the visibility of various mediastinal great vessels on 2D SSh bSSFP images. Raw agreement, the weighted kappa statistic, and intra-class correlation coefficients (ICCs) were computed to assess the consistency and agreement between the two readers. Comparative analysis of noncontrast and contrast-enhanced 3D bSSFP imaging was performed in adult and pediatric patients using a two-sided paired t-test and Bland-Altman analysis. A P-value < 0.05 was considered significant for all inference testing.
resultsA total of 29 patients (17 males, median age 20.3 years, interquartile range (IQR) 12.5, age range 7-39 years), including 11 pediatric patients under the age of 18 years (6 males, median age 14.5 years, IQR 4.0, age range 7-17 years), underwent retrospective analysis. The overall image quality score for contrast-enhanced 3D bSSFP was significantly higher (P < 0.0001) than that of noncontrast 3D bSSFP for both all subjects (4.4 ± 0.2, range 4.0-4.9 vs 3.7 ± 0.4, range 3.1-4.7) and only pediatric subjects (4.3 ± 0.3, range 4.0-4.9 vs 3.6 ± 0.5, range 3.1-4.4). By combining noncontrast 3D bSSFP and 2D bSSFP, reader 1 and reader 2 rated 423 and 420 vessels diagnostic, respectively, in a total of 435 vessel segments. All landmarks showed similar mean vessel diameters without significant differences between noncontrast and contrast-enhanced 3D bSSFP MR angiography (r = 0.99, bias -0.31 mm, 95% limits of agreement -2.04 mm to 1.43 mm).
conclusionsAlthough contrast-enhanced images had better overall image quality, an imaging protocol consisting of noncontrast 2D SSh bSSFP and 3D bSSFP whole-chest images provides diagnostically adequate image quality, and accurate vascular measurements, comparable to free-breathing contrast-enhanced 3D bSSFP in both children and adults with CHD and aortopathies.
Indexed as
Identifiers
39164501What Socratic holds
Registered trials