Evidence map›Paper›PMID 39200207›Full record

ArticleBiomedicines2024

Ultrasound-Compatible Electrode for Functional Electrical Stimulation.

Sunho Moon, Xiangming Xue, Vidisha Ganesh, Darpan Shukla, Benjamin C Kreager, Qianqian Cai, Huaiyu Wu, Yong Zhu, Nitin Sharma, Xiaoning Jiang

Abstract read
In one paragraph

Article in Biomedicines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Sunho MoonThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.ORCID 0000-0001-6059-171X
Xiangming XueThe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.ORCID 0000-0002-1399-0563
Vidisha GaneshThe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.
Darpan ShuklaThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.
Benjamin C KreagerThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.
Qianqian CaiThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.
Huaiyu WuThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.ORCID 0000-0003-2616-1171
Yong ZhuThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.
Nitin SharmaThe Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695, USA.ORCID 0000-0003-1872-0156
Xiaoning JiangThe Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27606, USA.

Funding

SCH: A personalized wearable rehabilitation sensing system for stroke survivorsR01HD108473 · NICHD · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI BARATTA, JOHN, BOZKURT, ALPER · 2021 to 2024
$1.1M
Data-driven Modeling and Ultrasound-based Control of Afferent Nerve Stimulation for Tremor SuppressionR21EB032059 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI SHARMA, NITIN · 2021 to 2023
$526k
National Science Foundation 2124017NIBIB NIH HHS R21 EB032059NICHD NIH HHS R01 HD108473NIH HHS 1R01HD108473NIH HHS R21EB032059
6 · The paper itself

Abstract

Functional electrical stimulation (FES) is a vital method in neurorehabilitation used to reanimate paralyzed muscles, enhance the size and strength of atrophied muscles, and reduce spasticity. FES often leads to increased muscle fatigue, necessitating careful monitoring of the patient's response. Ultrasound (US) imaging has been utilized to provide valuable insights into FES-induced fatigue by assessing changes in muscle thickness, stiffness, and strain. Current commercial FES electrodes lack sufficient US transparency, hindering the observation of muscle activity beneath the skin where the electrodes are placed. US-compatible electrodes are essential for accurate imaging and optimal FES performance, especially given the spatial constraints of conventional US probes and the need to monitor muscle areas directly beneath the electrodes. This study introduces specially designed body-conforming US-compatible FES (US-FES) electrodes constructed with a silver nanowire/polydimethylsiloxane (AgNW/PDMS) composite. We compared the performance of our body-conforming US-FES electrode with a commercial hydrogel electrode. The findings revealed that our US-FES electrode exhibited comparable conductivity and performance to the commercial one. Furthermore, US compatibility was investigated through phantom and in vivo tests, showing significant compatibility even during FES, unlike the commercial electrode. The results indicated that US-FES electrodes hold significant promise for the real-time monitoring of muscle activity during FES in clinical rehabilitative applications.

Indexed as

body-conforming ultrasound-compatible electrodefunctional electrical stimulation (FES)silver nanowire (AgNW) electrodeultrasound (US)wearable ultrasound

Identifiers

PMID39200207
PMCPMC11352097

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.