Evidence map›Paper›PMID 39207642›Full record

ArticleJapanese journal of radiology2024

Predicting the O'Kelly-Marotta scale score after flow-diverter stent placement using silent MRA.

Aki Miyazaki, Mizuho Nishio, Atsushi Fujita, Masaaki Kohta, Yasuyuki Kojita, Shintaro Horii, Takashi Sasayama, Takamichi Murakami

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Aki MiyazakiDepartment of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan. akican901@clear.ocn.ne.jp.ORCID http://orcid.org/0009-0007-0603-8308
Mizuho NishioDepartment of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Atsushi FujitaDepartment of Neurosurgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Masaaki KohtaDepartment of Neurosurgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Yasuyuki KojitaDepartment of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Shintaro HoriiCenter for Radiology and Radiation Oncology, Kobe University Hospital, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Takashi SasayamaDepartment of Neurosurgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.
Takamichi MurakamiDepartment of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-Cho, Chuo-Ku, Kobe, 650-0017, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeFlow-diverter (FD) stents were developed to treat aneurysms that are difficult to treat with conventional coiling or surgery. This study aimed to compare usefulness of Silent MRA and TOF (time of flight) -MRA in patients with aneurysms after FD placement. MATERIALS AND

methodsWe retrospectively collected images from 22 patients with 23 internal carotid artery aneurysms treated with FD. Two radiologists conducted MRA and DSA experiments. In the first reading experiment, the radiologists evaluated the aneurysm filling by employing Silent MRA and TOF-MRA and utilizing the modified O'Kelly-Marotta (OKM) scale, a four-class classification system for aneurysms after FD placement. We then calculated the agreement between the modified OKM scale on MRA and the original OKM scale on DSA. In the second reading experiment, the radiologists rated blood flow within the FD using a five-point scale.

resultsThe weighted kappa value of the OKM scale between DSA and TOF-MRA was 0.436 (moderate agreement), and that between DSA and Silent MRA was 0.943 (almost perfect agreement). The accuracies for the four-class classification were 0.435 and 0.870 for TOF-MRA and Silent MRA, respectively. The mean score of blood flow within FD for TOF-MRA was 2.43 ± 0.90 and that for Silent MRA was 3.04 ± 1.02 (P < 0.001).

conclusionSilent MRA showed a higher degree of agreement than TOF-MRA in aneurysm filling with DSA. In addition, Silent MRA was significantly superior to TOF-MRA in depicting blood flow within the FD. Therefore, Silent MRA is clinically useful for the follow-up of patients after FD placement.

Indexed as

Magnetic Resonance AngiographyStentsAdultAgedAged, 80 and overAneurysmAngiography, Digital SubtractionCarotid Artery DiseasesCarotid Artery, InternalFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeDSAFlow-diverterMRAO'Kelly-Marotta grading scaleSilent MRA

Identifiers

PMID39207642
PMCPMC11588759

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.