Evidence map›Paper›PMID 39223768›Full record

ArticleArchives of craniofacial surgery2024

Usability testing of a novel interlocking three-dimensional miniplate for mandibular angle fractures.

Prasetyanugraheni Kreshanti, Aria Kekalih, Ahmad Jabir Rahyussalim, Sugeng Supriadi, Bambang Pontjo Priosoeryanto, Deni Noviana, Mendy Hatibie Oley, Chaula Luthfia Sukasah

Abstract read
In one paragraph

Article in Archives of craniofacial surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Prasetyanugraheni KreshantiDoctoral Program in Medical Sciences, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
Aria KekalihDepartment of Community Medicine, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
Ahmad Jabir RahyussalimDepartment of Orthopaedics and Traumatology, Dr. Cipto Mangunkusumo Hospital, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
Sugeng SupriadiResearch Center for Biomedical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI, Depok, Indonesia.
Bambang Pontjo PriosoeryantoDivision of Veterinary Pathology, School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia.
Deni NovianaDivision of Surgery and Radiology, School of Veterinary Medicine and Biomedical Sciences, IPB University, Bogor, Indonesia.
Mendy Hatibie OleyDivision of Plastic Reconstructive and Aesthetic Surgery, Department of Surgery, Faculty of Medicine, Sam Ratulangi University, Manado, Indonesia.
Chaula Luthfia SukasahDivision of Plastic Reconstructive and Aesthetic Surgery, Department of Surgery, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.

Funding

Universitas Indonesia NKB-592/UN2.RST/HKP.05.00/2020
6 · The paper itself

Abstract

backgroundWe developed a novel interlocking three-dimensional (3D) miniplate design with an adjustable configuration. As this device is new, surgeons must become familiar with its application. This study evaluated the usability and learning curves associated with the novel interlocking 3D miniplate for mandibular fracture fixation.

methodsThe study participants, nine plastic surgeons, were asked to apply an interlocking 3D miniplate and a standard miniplate to polyurethane mandible models. The participants had completed the Basic Craniomaxillofacial Osteosynthesis course during residency and had operated on craniomaxillofacial fractures within the past 5 years. They were instructed to place the interlocking 3D miniplate three times and the standard miniplate once. We assessed the time required for implant placement, the comfort level of the surgeons, and the biomechanical stability of the plates. Biomechanical testing was conducted by subjecting the mandible to forces ranging from 10 to 90 N and the displacement was measured.

resultsThe results indicate increasing comfort with each attempt at placing the interlocking 3D miniplate, with a significant difference between the first and third attempts. Additionally, a reduction in application time was noted with repeated attempts, suggesting improved efficiency. Biomechanical tests showed comparable stability between the tested plates.

conclusionMultiple attempts at applying the interlocking 3D miniplate resulted in increased comfort and reduced application time. These findings indicate that, despite its novelty, the interlocking 3D miniplate is relatively straightforward to apply and has a short learning curve. However, surgeons must have specific qualifications to ensure proper training and minimize errors during placement.

Indexed as

Fracture fixation, internalMandibular fracturesUsability testing

Identifiers

PMID39223768
PMCPMC11374522

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.