Evidence map›Paper›PMID 39269959›Full record

ArticlePloS one2024

Assessment of material identification and quantification in the presence of metals using spectral photon counting CT.

Briya Tariq, Osama Sikander, Nadine Francis, Manar Alkhatib, Farhat Naseer, Naoufel Werghi, Esat Memisoglu, Nabil Maalej, Aamir Raja

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Briya TariqDepartment of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.ORCID 0009-0006-7881-4399
Osama SikanderDepartment of Biomedical Engineering & Sciences, National University of Sciences and Technology, Islamabad, Pakistan.
Nadine FrancisDepartment of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.
Manar AlkhatibDepartment of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.
Farhat NaseerDepartment of Robotics and Intelligent Machine Engineering, National University of Sciences and Technology, Islamabad, Pakistan.
Naoufel WerghiDepartment of Electrical & Computer Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
Esat MemisogluImaging Institute, Cleveland Clinic Abu Dhabi, Abu Dhabi, United Arab Emirates.
Nabil MaalejDepartment of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.
Aamir RajaDepartment of Physics, Khalifa University, Abu Dhabi, United Arab Emirates.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Spectral Photon Counting Computed Tomography (SPCCT), a ground-breaking development in CT technology, has immense potential to address the persistent problem of metal artefacts in CT images. This study aims to evaluate the potential of Mars photon-counting CT technology in reducing metal artefacts. It focuses on identifying and quantifying clinically significant materials in the presence of metal objects. A multi-material phantom was used, containing inserts of varying concentrations of hydroxyapatite (a mineral present in teeth, bones, and calcified plaque), iodine (used as a contrast agent), CT water (to mimic soft tissue), and adipose (as a fat substitute). Three sets of scans were acquired: with aluminium, with stainless steel, and without a metal insert as a reference dataset. Data acquisition was performed using a Mars SPCCT scanner (Microlab 5×120); operated at 118 kVp and 80 μA. The images were subsequently reconstructed into five energy bins: 7-40, 40-50, 50-60, 60-79, and 79-118 keV. Evaluation metrics including signal-to-noise ratio (SNR), linearity of attenuation profiles, root mean square error (RMSE), and area under the curve (AUC) were employed to assess the energy and material-density images with and without metal inserts. Results show decreased metal artefacts and a better signal-to-noise ratio (up to 25%) with increased energy bins as compared to reference data. The attenuation profile also demonstrated high linearity (R2 >0.95) and lower RMSE across all material concentrations, even in the presence of aluminium and steel. Material identification accuracy for iodine and hydroxyapatite (with and without metal inserts) remained consistent, minimally impacting AUC values. For demonstration purposes, the biological sample was also scanned with the stainless steel volar implant and cortical bone screw, and the images were objectively assessed to indicate the potential effectiveness of SPCCT in replicating real-world clinical scenarios.

Indexed as

MetalsPhantoms, ImagingPhotonsTomography, X-Ray ComputedArtifactsDurapatiteHumansIodineSignal-To-Noise RatioDurapatiteIodineMetals

Identifiers

PMID39269959
PMCPMC11398698

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked