ArticleQuantitative imaging in medicine and surgery2024

Optimization of motion-corrected liver diffusion-weighted imaging at 3 Tesla (3T): incorporating complex averaging and reparametrized sinc fatsat pulse with optimized water excitation pulse.

Zhiyong Chen, Zhangli Xing, Enshuang Zheng, Mingcong Luo, Caixia Fu, Guijin Li, Thomas Benkert, Yunjing Xue, Bin Sun

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zhiyong Chen *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Zhangli Xing *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Enshuang ZhengDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Mingcong LuoDepartment of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Caixia FuMR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China.
Guijin LiMR Application, Siemens Healthineers Ltd., Guangzhou, China.
Thomas BenkertMR Application Predevelopment, Siemens Healthineers AG, Erlangen, Germany.
Yunjing Xue *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.
Bin Sun *Department of Radiology, Fujian Medical University Union Hospital, Fuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In liver diffusion-weighted imaging (DWI), single-shot echo-planar imaging (SS-EPI) sequences are susceptible to motion artifacts, resulting in image blurring and decreased lesion detection rates. This study aimed to develop and optimize a motion-corrected (MOCO) technique for liver DWI at 3 Tesla (3T). The technique incorporates motion correction, complex averaging, and a combination of a reparametrized sinc fatsat pulse with an optimized water excitation pulse. Methods: This prospective cross-sectional study performed at Fujian Medical University Union Hospital included 42 healthy volunteers who underwent four SS-EPI DWI sequences on a 3T magnetic resonance imaging (MRI) system between January 2023 and March 2023. The sequences included a navigator-triggered (NT) MOCO-DWI, two free-breathing (FB) MOCO-DWI, and an FB conventional DWI (FB cDWI) sequence. Motion correction and complex averaging were performed for both MOCO-DWI sequences, and fat suppression was achieved using either a sinc fatsat pulse with optimized water excitation or a conventional spectral attenuated inversion recovery (SPAIR) pulse. Liver signal-to-noise ratio (SNR) was measured at b=1,000 s/mm Results: The SNRs of the liver were significantly higher with FB MOCO-DWI compared to the other EPI DWI sequences at b=1,000 s/mm Conclusions: The proposed EPI DWI technique, incorporating motion correction, complex averaging, and a modified fat suppression scheme using spectral fat saturation and binomial water excitation, was found to be clinically feasible for liver MRI. The FB MOCO-DWI sequence, with its superior SNR and excellent image quality, is recommended for liver DW imaging at 3T in clinical routine.

Indexed as

Diffusion-weighted imaging (DWI)free-breathing (FB)livermagnetic resonance imaging (MRI)motion-corrected (MOCO)