ReviewProgress in retinal and eye research2024
The relationship between intraocular pressure and glaucoma: An evolving concept.
Review in Progress in retinal and eye research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 63 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
63 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Efficacy and safety of stem cells in the treatment of glaucoma: systematic review and meta-analysis based on animal experiments.Frontiers in pharmacology · 2025Pooled it
- Efficacy and safety of prostaglandin drugs for elevated intraocular pressure: a Bayesian network meta-analysis.Frontiers in medicine · 2025Pooled it
- Hierarchical ROS-scavenging hydrogel system for coordinating the modulation of RGC necroptosis and oxidative stress in an acute glaucoma model.Bioactive materials · 2026Article
- The impact of iCare HOME tonometry on clinical decision-making in glaucoma management: a retrospective observational study.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Validation of Automated Fixed Force Applanation Tonometry.Ophthalmology science · 2026Article
- Effects of short-term moderate versus high intraocular pressure elevation on flicker-induced changes in full-field electroretinogram.Documenta ophthalmologica. Advances in ophthalmology · 2026Article
- PEBP1 Regulates Ferroptosis in Acute Glaucoma: Targeted Therapy Using Engineered Exosomes.FASEB journal : official publication of the Federation of American Societies for Experimental Biology · 2026Article
- Review
- Research Progress of Diabetes-related Glaucoma: Mechanisms, Impacts and Management Strategies.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026Review
- Latanoprost Acid-Brimonidine, a New Amide Prodrug for Glaucoma Management Based on the Concept of Sustained Release.Molecules (Basel, Switzerland) · 2026Article
- Presence of Obsessionality and Hysteria in Patients with Primary Open-Angle Glaucoma.Medicina (Kaunas, Lithuania) · 2026Article
- The Dual Role of Macroglia in Glaucoma: Deciphering the Contributions of Astrocytes and Müller Cells to Retinal Neurodegeneration and Neuroprotection.International journal of molecular sciences · 2026Review
- Innovations in glaucoma treatment: development and testing of a novel self-adjustable implant for effective pressure regulation.Microsystems & nanoengineering · 2026Article
- Beyond intraocular pressure: vascular and metabolic modifiers of optic nerve vulnerability in glaucoma.International ophthalmology · 2026Review
- Lithium as a Potential Neuroprotective Strategy in Glaucoma: Mechanisms and Therapeutic Perspectives.Biomolecules · 2026Review
- Assessment of anti-VEGF intravitreal injection effects on murine neonatal Schlemm's canal morphology.Scientific reports · 2026Article
- Validation of a New Handheld Automated Fixed-Force Applanation Tonometer.Translational vision science & technology · 2026Article
- Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Increased Risk of Intraocular Pressure-Lowering Treatment in Patients with End-Stage Renal Disease Undergoing Hemodialysis.Ophthalmology. Glaucoma · 2026Article
- Ion-Pair-Tuned Ionogels for Broad-Range Linear Pressure Sensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
3 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Intraocular pressure (IOP) is the most important modifiable risk factor for glaucoma and fluctuates considerably within patients over short and long time periods. Our field's understanding of IOP has evolved considerably in recent years, driven by tonometric technologies with increasing accuracy, reproducibility, and temporal resolution that have refined our knowledge regarding the relationship between IOP and glaucoma risk and pathogenesis. The goal of this article is to review the published literature pertinent to the following points: 1) the factors that determine IOP in physiologic and pathologic states; 2) technologies for measuring IOP; 3) scientific and clinical rationale for measuring diverse IOP metrics in patients with glaucoma; 4) the impact and shortcomings of current standard-of-care IOP monitoring approaches; 5) recommendations for approaches to IOP monitoring that could improve patient outcomes; and 6) research questions that must be answered to improve our understanding of how IOP contributes to disease progression. Retrospective and prospective data, including that from landmark clinical trials, document greater IOP fluctuations in glaucomatous than healthy eyes, tendencies for maximal daily IOP to occur outside of office hours, and, in addition to mean and maximal IOP, an association between IOP fluctuation and glaucoma progression that is independent of mean in-office IOP. Ambulatory IOP monitoring, measuring IOP outside of office hours and at different times of day and night, provides clinicians with discrete data that could improve patient outcomes. Eye care clinicians treating glaucoma based on isolated in-office IOP measurements may make treatment decisions without fully capturing the entire IOP profile of an individual. Data linking home blood pressure monitors and home glucose sensors to dramatically improved outcomes for patients with systemic hypertension and diabetes and will be reviewed as they pertain to the question of whether ambulatory tonometry is positioned to do the same for glaucoma management. Prospective randomized controlled studies are warranted to determine whether remote tonometry-based glaucoma management might reduce vision loss and improve patient outcomes.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.