ArticleAmerican journal of nuclear medicine and molecular imaging2024
Accurate brain pharmacokinetic parametric imaging using the blood input function extracted from the cavernous sinus.
Article in American journal of nuclear medicine and molecular imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Brain pharmacokinetic parametric imaging based on dynamic positron emission tomography (PET) scan is valuable in the diagnosis of brain tumor and neurodegenerative diseases. For short-axis PET system, standard blood input function (BIF) of the descending aorta is not acquirable during the dynamic brain scan. BIF extracted from the intracerebral vascular is inaccurate, making the brain parametric imaging task challenging. This study introduces a novel technique tailored for brain pharmacokinetic parameter imaging in short-axis PET in which the head BIF (hBIF) is acquired from the cavernous sinus. The proposed method optimizes the hBIF within the Patlak model via data fitting, curve correction and Patlak graphical model rewriting. The proposed method was built and evaluated using dynamic PET datasets of 67 patients acquired by uEXPLORER PET/CT, among which 64 datasets were used for data fitting and model construction, and 3 were used for method testing; using cross-validation, a total of 15 patient datasets were finally used to test the model. The performance of the new method was evaluated via visual inspection, root-mean-square error (RMSE) measurements and VOI-based accuracy analysis using linear regression and Person's correlation coefficients (PCC). Compared to directly using the cavernous sinus BIF directly for parameter imaging, the new method achieves higher accuracy in parametric analysis, including the generation of Patlak plots closer to the standard plots, better visual effects and lower RMSE values in the
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.