Evidence map›Paper›PMID 39328472›Full record

ArticleInternational journal of cardiology. Heart & vasculature2024

Comparison of the effects of contrast medium and low-molecular-weight dextran on coronary optical coherence tomographic imaging in relatively complex coronary lesions.

Junyan Zhang, Minggang Zhou, Yong Chen, Zhongxiu Chen, Hua Wang, Chen Li, Yong He

Abstract read
In one paragraph

Article in International journal of cardiology. Heart & vasculature, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Junyan ZhangDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Minggang ZhouDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Yong ChenDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Zhongxiu ChenDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Hua WangDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Chen LiDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.
Yong HeDepartment of Cardiology, West China Hospital of Sichuan University, Chengdu, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Optical coherence tomography (OCT) has gained increasing popularity in coronary artery intervention due to its high resolution and excellent tissue correlation as a novel intravascular imaging modality. However, the current use of OCT requires contrast agent injection for imaging, and excessive use of contrast agents may adversely affect renal function, exacerbate cardiac burden, and even lead to contrast agent-induced nephropathy and heart failure. In recent years, several researchers have proposed the use of low molecular weight dextran (LMWD) as a substitute for contrast agents in OCT imaging because of its low toxicity, low cost, and wide availability. However, the inclusion of lesions in these studies is relatively simple, and the image quality criteria remain to be optimized. Methods: This study included 26 patients with coronary artery disease who were scheduled for OCT imaging in a real-world clinical practice involving various complex lesions. All patients underwent two OCT examinations at the same vascular site, one each using contrast agent and LMWD. Both contrast media and LMWDs were infused by an autoinjector. The primary endpoint of the study was the average image quality score. Secondary endpoints included clear image length, clear image segments, minimum lumen area, average lumen area, and contrast-induced nephropathy, among others. Results: In terms of image clarity, the average image quality score was similar when comparing contrast media with LMWD (3.912 ± 0.175 vs. 3.769 ± 0.392, P = 0.071). The lengths of the clear images and the segments of the clear images were also similar between the two groups (50.97 ± 16.25 mm vs. 49.12 ± 18.15 mm, P = 0.110; 255.5 ± 81.29 vs. 250.5 ± 89.83, P = 0.095). Additionally, strong correlations were noted between the two flushing solutions regarding the minimum lumen area and mean lumen area. During their hospital stay, none of the patient exhibited deterioration in renal function, and no patient experienced any major adverse cardiovascular events. Conclusions: The quality of coronary artery OCT imaging using LMWD may be comparable to that achieved with traditional contrast agents, even in real-world clinical practice involving various complex lesions. For high-risk patients, LMWD may serve as an excellent substitute for contrast agents in OCT examinations.

Indexed as

Contrast mediaIntracoronary imagingLow-molecular-weight dextranOptical coherence tomography

Identifiers

PMID39328472
PMCPMC11426137

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.