ArticleBiomedicines2024
In Silico Investigation of the Interlaminar and Mechanical Fracture of Arteries with Atheromatic Plaque during Angioplasty Treatment.
Article in Biomedicines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Computational modeling of drug-eluting balloons in peripheral artery disease: Mechanisms, optimization, and translational insights.Computational and structural biotechnology journal · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The reduction in the inner diameter of the artery due to the creation of atheromatic plaque on the artery lumen, known as artery stenosis, disrupts the blood flow, leading to medical complications, which can be fatal. The angioplasty procedure aims to reopen the artery and uses a stent to keep it open. In this study, an effort is made to determine the point of the stent, the plaque and the artery during the expansion phase of the angioplasty using the in silico Finite Element Analysis method. A literature-based design was chosen for the stent geometry, whereas simplified shapes of the balloon and the two artery layers were used. Additionally, two plaque designs were the benchmark for the eight distinct artery stenosis models within the Abaqus environment. In the context of stent angioplasty simulations, failure patterns were investigated. An inverse relationship was observed between artery stenosis and pressure at the artery failure point, while an increased danger of interlaminar failure was detected in models with larger artery stenosis. This study verifies the necessity for the inclusion of interlaminar failure in future angioplasty research.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.