Evidence map›Paper›PMID 39340153›Full record

ArticleBiophysical journal2024

The dynamics of red blood cells traversing slits of mechanical heart valves under high shear.

Kuilin Meng, Haosheng Chen, Yunfan Pan, Yongjian Li

Abstract read
In one paragraph

Article in Biophysical journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kuilin MengState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China.
Haosheng ChenState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China.
Yunfan PanState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China.
Yongjian LiState Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing, China. Electronic address: liyongjian@tsinghua.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hemolysis, including subclinical hemolysis, is a potentially severe complications of mechanical heart valves (MHVs), which leads to shortened red blood cell (RBC) lifespan and hemolytic anemia. Serious hemolysis is usually associated with structural deterioration and regurgitation. However, the shear stress in MHVs' narrow leakage slits is much lower than the shear stress threshold causing hemolysis and the mechanisms in this context remain largely unclear. This study investigated the hemolysis mechanism of RBCs in cell-size slits under high shear rates by establishing in vitro microfluidic devices and a coarse-grained molecular dynamics (CGMD) model, considering both fluid and structural effects simultaneously. Microfluidic experiments and computational simulation revealed six distinct dynamic states of RBC traversal through MHVs' microscale slits under various shear rates and slit sizes. It elucidated that RBC dynamic states were influenced by not only by fluid forces but significantly by the compressive force of slit walls. The variation of the potential energy of the cell membrane indicated its stretching, deformation, and rupture during traversal, corresponding to the six dynamic states. The maximum forces exerted on membrane by water particles and slit walls directly determined membrane rupture, serving as a critical determinant. This analysis helps in understanding the contribution of the slit walls to membrane rupture and identifying the threshold force that leads to membrane rupture. The hemolysis mechanism of traversing microscale slits is revealed to effectively explain the occurrences of hemolysis and subclinical hemolysis.

Indexed as

ErythrocytesHemolysisStress, MechanicalBiomechanical PhenomenaHeart Valve ProsthesisHumansMolecular Dynamics SimulationShear Strength

Identifiers

PMID39340153
PMCPMC11560308

What Socratic holds