Evidence map›Paper›PMID 39346996›Full record

ArticleBiomedical optics express2024

Exploring single-mode VCSEL wavelength tuning for low-cost 3D optical coherence tomography and OCT angiography.

Milana Kendrisic, Jonas Nienhaus, Vladislav Agafonov, Matthias Salas, Quang Nguyen, Hemma Resch, Clemens Vass, Wolfgang Drexler, Tilman Schmoll, Rainer A Leitgeb

Abstract read
In one paragraph

Article in Biomedical optics express, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Milana KendrisicCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Jonas NienhausCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Vladislav AgafonovCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Matthias SalasCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Quang NguyenCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Hemma ReschDepartment of Ophthalmology and Optometry, Vienna General Hospital, Vienna 1090, Austria.
Clemens VassDepartment of Ophthalmology and Optometry, Vienna General Hospital, Vienna 1090, Austria.
Wolfgang DrexlerCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Tilman SchmollCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.
Rainer A LeitgebCenter for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna 1090, Austria.ORCID https://orcid.org/0000-0002-0131-4111

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Low-cost optical coherence tomography has recently emerged as a growing field due to the increased need for general availability of OCT devices outside of the clinics. One of the main obstacles in creating low-cost SS-OCT systems is the price of the laser. In this work, we study the influence of different tuning parameters (e.g., frequency, duty cycle, modulation curve, temperature) on the resulting bandwidth of the previously proposed low-cost single-mode thermally-tunable vertical-cavity surface-emitting laser (VCSEL) source at 850 nm. With optimal parameters, the laser achieves a tuning bandwidth of 10.2 nm at a 50 kHz A-scan rate. In addition, we show the first 3D rendered volume scans of both anterior and posterior segment using a custom VCSEL-based low-cost OCT setup. With the help of deep-learning-based denoising, it was possible to critically reduce the noise in single scans. Moreover, by investigating the phase stability, it became apparent that phase stability between sweeps increases with rising modulation frequencies, making the auxiliary interferometer obsolete. Thus, the system's 50 kHz tuning regimen is also suitable for functional extensions such as OCT angiography.

Identifiers

PMID39346996
PMCPMC11427204

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.