Evidence map›Paper›PMID 39361400›Full record

ArticleJMIR formative research2024

Ability of Heart Rate Recovery and Gait Kinetics in a Single Wearable to Predict Frailty: Quasiexperimental Pilot Study.

Reshma Aziz Merchant, Bernard Loke, Yiong Huak Chan

Abstract read
In one paragraph

Article in JMIR formative research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Reshma Aziz Merchant *Division of Geriatric Medicine, Department of Medicine, National University Hospital, Singapore, Singapore.ORCID 0000-0002-9032-0184
Bernard Loke *Biologic Technik, Singapore, Singapore.ORCID 0009-0005-8443-5929
Yiong Huak ChanBiostatistics Unit, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.ORCID 0000-0002-5076-5269

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAging is a risk factor for falls, frailty, and disability. The utility of wearables to screen for physical performance and frailty at the population level is an emerging research area. To date, there is a limited number of devices that can measure frailty and physical performance simultaneously.

objectiveThe aim of this study is to evaluate the accuracy and validity of a continuous digital monitoring wearable device incorporating gait mechanics and heart rate recovery measurements for detecting frailty, poor physical performance, and falls risk in older adults at risk of falls.

methodsThis is a substudy of 156 community-dwelling older adults ≥60 years old with falls or near falls in the past 12 months who were recruited for a fall prevention intervention study. Of the original participants, 22 participants agreed to wear wearables on their ankles. An interview questionnaire involving demographics, cognition, frailty (FRAIL), and physical function questions as well as the Falls Risk for Older People in the Community (FROP-Com) was administered. Physical performance comprised gait speed, timed up and go (TUG), and the Short Physical Performance Battery (SPPB) test. A gait analyzer was used to measure gait mechanics and steps (FRAIL-functional: fatigue, resistance, and aerobic), and a heart rate analyzer was used to measure heart rate recovery (FRAIL-nonfunctional: weight loss and chronic illness).

resultsThe participants' mean age was 74.6 years. Of the 22 participants, 9 (41%) were robust, 10 (46%) were prefrail, and 3 (14%) were frail. In addition, 8 of 22 (36%) had at least one fall in the past year. Participants had a mean gait speed of 0.8 m/s, a mean SPPB score of 8.9, and mean TUG time of 13.8 seconds. The sensitivity, specificity, and area under the curve (AUC) for the gait analyzer against the functional domains were 1.00, 0.84, and 0.92, respectively, for SPPB (balance and gait); 0.38, 0.89, and 0.64, respectively, for FRAIL-functional; 0.45, 0.91, and 0.68, respectively, for FROP-Com; 0.60, 1.00, and 0.80, respectively, for gait speed; and 1.00, 0.94, and 0.97, respectively, for TUG. The heart rate analyzer demonstrated superior validity for the nonfunctional components of frailty, with a sensitivity of 1.00, specificity of 0.73, and AUC of 0.83.

conclusionsAgreement between the gait and heart rate analyzers and the functional components of the FRAIL scale, gait speed, and FROP-Com was significant. In addition, there was significant agreement between the heart rate analyzer and the nonfunctional components of the FRAIL scale. The gait and heart rate analyzers could be used in a screening test for frailty and falls in community-dwelling older adults but require further improvement and validation at the population level.

Indexed as

Accidental FallsFrailtyGaitHeart RateWearable Electronic DevicesAgedAged, 80 and overFemaleFrail ElderlyGeriatric AssessmentHumansIndependent LivingMaleMiddle AgedPilot Projectsbiomechanicscommunity dwelling older adultsfall preventionfallsgaitgait analysisgait kineticsgerontologyolder adultsensorswearables

Identifiers

PMID39361400
PMCPMC11487206

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.