ArticleScientific reports2024

Validation and user experience of a dry electrode based Health Patch for heart rate and respiration rate monitoring.

Jonathan C J Wei, Tim J van den Broek, Jan Ubbo van Baardewijk, Robin van Stokkum, Regina J M Kamstra, Lars Rikken, Kaj Gijsbertse, Natallia Eduarda Uzunbajakava, Willem J van den Brink

Abstract readValidation Study
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jonathan C J WeiMicrobiology & Systems Biology, TNO (Netherlands Organisation for Applied Scientific Research), Leiden, The Netherlands.
Tim J van den BroekMicrobiology & Systems Biology, TNO (Netherlands Organisation for Applied Scientific Research), Leiden, The Netherlands.
Jan Ubbo van BaardewijkHuman Performance, TNO (Netherlands Organisation for Applied Scientific Research), Soesterberg, The Netherlands.
Robin van StokkumRisk Analysis for Products in Development, TNO (Netherlands Organisation for Applied Scientific Research), Utrecht, The Netherlands.
Regina J M KamstraMicrobiology & Systems Biology, TNO (Netherlands Organisation for Applied Scientific Research), Leiden, The Netherlands.
Lars RikkenHolst Centre, TNO (Netherlands Organisation for Applied Scientific Research), Eindhoven, The Netherlands.
Kaj GijsbertseHuman Performance, TNO (Netherlands Organisation for Applied Scientific Research), Soesterberg, The Netherlands.
Natallia Eduarda UzunbajakavaHolst Centre, TNO (Netherlands Organisation for Applied Scientific Research), Eindhoven, The Netherlands. natallia.uzunbajakava@tno.nl.
Willem J van den BrinkMicrobiology & Systems Biology, TNO (Netherlands Organisation for Applied Scientific Research), Leiden, The Netherlands. willem.vandenbrink@tno.nl.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Successful implementation of remote monitoring of vital signs outside of the hospital setting hinges on addressing three crucial unmet needs: longer-term wear, skin comfort and signal quality. Earlier, we developed a Health Patch research platform that uses self-adhesive dry electrodes to measure vital digital biomarkers. Here, we report on the analytical validation for heart rate, heart rate variability and respiration rate. Study design included n = 25 adult participants with data acquisition during a 30-minute exercise protocol involving rest, squats, slow, and fast cycling. The Shimmer3 ECG Unit and Cosmed K5, were reference devices. Data analysis showed good agreement in heart rate and marginal agreement in respiratory rate, with lower agreement towards higher respiratory rates. The Lin's concordance coefficient was 0.98 for heart rate and 0.56 for respiratory rate. Heart rate variability (RMSSD) had a coefficient of 0.85. Participants generally expressed a positive experience with the technology, with some minor irritation from the medical adhesive. The results highlighted potential of this technology for short-to-medium term clinical use for cardiorespiratory health, due to its reliability, accuracy, and compact design. Such technology could become instrumental for remote monitoring providing healthcare professionals with continuous data, remote assessment and enhancing patient outcomes in cardiorespiratory health management.

Indexed as

ElectrodesHeart RateRespiratory RateAdultElectrocardiographyFemaleHumansMaleMiddle AgedMonitoring, PhysiologicReproducibility of ResultsWearable Electronic DevicesYoung Adult