Evidence map›Paper›PMID 39367356›Full record

ArticleBMC musculoskeletal disorders2024

Utilizing radiomics techniques to isolate a single vertebral body from chest CT for opportunistic osteoporosis screening.

Xiaocong Lin, Rongkai Shen, Xiaoling Zheng, Shaojian Shi, Zhangsheng Dai, Kaibin Fang

Abstract readMulticenter Study
In one paragraph

Article in BMC musculoskeletal disorders, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Radiomics in spinal research: a narrative review.Frontiers in bioengineering and biotechnology · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiaocong Lin *Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, 950 Donghai Street, Fengze District, Quanzhou, Fujian, 362000, China.
Rongkai Shen *Department of Orthopaedic Surgery, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350000, China.
Xiaoling ZhengLiming Vocational University, Quanzhou, 362000, China.
Shaojian ShiJinjiang General Hospital, Jinjiang, 362200, China.
Zhangsheng DaiDepartment of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, 950 Donghai Street, Fengze District, Quanzhou, Fujian, 362000, China.
Kaibin FangDepartment of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, 950 Donghai Street, Fengze District, Quanzhou, Fujian, 362000, China. cffkb00@fjmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeOpportunistic osteoporosis screening, conducted during routine medical examinations such as chest computed tomography (CT), presents a potential solution for early detection. This study aims to investigate the feasibility of utilizing radiomics technology based on chest CT images to screen for opportunistic osteoporosis.

methodsThis Study is a Multicenter Retrospective Investigation. Relevant clinical data, including demographics and DXA results, would be collected for each participant. The radiomics analysis in this study focuses on the extraction of features from the 11th or 12th thoracic vertebral bodies from chest CT images. SVM machine learning models would be trained using these radiomic features, with DXA results as the ground truth for osteoporosis classification.

resultsIn the training group, Clinical models had an accuracy of 0.684 and an AUC of 0.744, Radiomics models had an accuracy of 0.828 and an AUC of 0.896, Nomogram models had an accuracy of 0.839 and an AUC of 0.901. In the internal validation group, Clinical models had an accuracy of 0.769 and an AUC of 0.829, Radiomics models had an accuracy of 0.832 and an AUC of 0.892, Nomogram models had an accuracy of 0.839 and an AUC of 0.918. In the external validation group, Clinical models had an accuracy of 0.715 and an AUC of 0.741, Radiomics models had an accuracy of 0.777 and an AUC of 0.796, Nomogram models had an accuracy of 0.785 and an AUC of 0.807. In all three datasets, the Nomogram model exhibited a statistically significant difference in screening effectiveness compared to the clinical models.

conclusionOur research demonstrates that by leveraging radiomics features extracted from a single thoracic spine using chest CT, and incorporating these features with patient basic information, opportunistic screening for osteoporosis can be achieved.

Indexed as

OsteoporosisThoracic VertebraeTomography, X-Ray ComputedAbsorptiometry, PhotonAgedFeasibility StudiesFemaleHumansMachine LearningMaleMass ScreeningMiddle AgedNomogramsRadiography, ThoracicRadiomicsRetrospective StudiesChest CTOsteoporosisRadiomicsThoracic vertebrae

Identifiers

PMID39367356
PMCPMC11451174

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.