Evidence map›Paper›PMID 39372676›Full record

Trial reportDrug design, development and therapy2024

Minimum Local Anesthetic Dose of Ropivacaine in Cesarean Section for Real-Time Ultrasound-Guided Spinal Anesthesia Using 24-Gauge versus 26-Gauge Needles Based on Fluid Simulation Technology: A Randomized Controlled Trial.

Chunying Zheng, Hanliang Fan, Peng Ye, Xing Zhang, Xiaochun Zheng, Ting Zheng

Abstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Drug design, development and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chunying Zheng *Department of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.
Hanliang Fan *Department of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.
Peng Ye *Department of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.
Xing ZhangDepartment of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.
Xiaochun ZhengDepartment of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.
Ting ZhengDepartment of Anesthesiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Previous research has demonstrated that real-time ultrasound-guided (UG) spinal anesthesia requires a higher minimum local anesthetic dose (MLAD) compared to traditional methods. However, the precise MLAD of ropivacaine for UG cesarean sections remains undetermined. In this study, we ascertained the MLAD of ropivacaine for cesarean section. We also investigated the mechanism underlying the diffusion of ropivacaine within the spinal canal using fluid simulation technology. Patients and Methods: We randomly placed 60 healthy parturients undergoing elective cesarean section with real-time UG spinal anesthesia into Groups I (26-gauge spinal needle) and II (24-gauge spinal needle). For the first parturient in both groups, 15 mg of ropivacaine was administered intrathecally. Based on the effective or ineffective response of the previous parturient, the dose for the subsequent parturient was increased or decreased by 1 mg. Spinal anesthesia characteristics and side effects were recorded. A computer-generated spinal canal model was developed. Leveraging fluid dynamics simulation technology, we documented the diffusion of ropivacaine in the spinal canal using 26-and 24-gauge spinal needles. Results: The MLADs in Groups I and II were 12.728 mg (12.339-13.130 mg) and 9.795 mg (9.491-10.110 mg), respectively. No significant difference was observed in the onset times and durations of sensory or motor blocks, incidence of complications, or neonatal Apgar scores between both groups. Fluid simulation modeling indicated that the 26-gauge spinal needle achieved a higher distribution level more quickly; however, its peak drug concentration was lower compared to the 24-gauge spinal needle. Conclusion: For cesarean section anesthetization, the required MLAD of ropivacaine when using a real-time UG 26-gauge spinal needle is significantly greater than that with a 24-gauge needle. The spinal needle diameter influences ropivacaine's MLAD by markedly affecting its diffusion rate within the spinal canal.

Indexed as

Anesthesia, SpinalAnesthetics, LocalCesarean SectionNeedlesRopivacaineAdultDose-Response Relationship, DrugFemaleHumansPregnancyUltrasonography, InterventionalAnesthetics, LocalRopivacaineanesthetic diffusioncesarean anesthetizationfluid dynamics simulationspinal needle diameter

Identifiers

PMID39372676
PMCPMC11453162

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.