Evidence map›Paper›PMID 39386222›Full record

ArticleBioactive materials2025

Semi-quantitative elemental imaging of corrosion products from bioabsorbable Mg vascular implants

Weilue He, Keith W MacRenaris, Adam Griebel, Maria P Kwesiga, Erico Freitas, Amani Gillette, Jeremy Schaffer, Thomas V O'Halloran, Roger J Guillory Ii

Abstract read
In one paragraph

Article in Bioactive materials, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Insights into the biological effects of molybdenum in an insect model (Frontiers in bioengineering and biotechnology · 2026
    Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Weilue HeDepartment of Biomedical Engineering, Michigan Technological University, USA.
Keith W MacRenarisDepartment of Microbiology, Genetics and Immunology (MGI) and Chemistry, Michigan State University, USA.
Adam GriebelFort Wayne Metals, Fort Wayne, IN, USA.
Maria P KwesigaDepartment of Biomedical Sciences, Grand Valley State University, USA.
Erico FreitasDepartment of Materials Science and Engineering, Michigan Technological University, USA.
Amani GilletteDepartment of Biomedical Engineering, Morgridge Institute for Research, USA.
Jeremy SchafferFort Wayne Metals, Fort Wayne, IN, USA.
Thomas V O'HalloranDepartment of Microbiology, Genetics and Immunology (MGI) and Chemistry, Michigan State University, USA.
Roger J Guillory IiJoint Department of Biomedical Engineering, Medical College of Wisconsin, Marquette University, USA.

Funding

TR&D Project 3: Photoacoustic Detection of Metal Fluxes at the Tissue LevelP41GM135018 · NIGMS · NORTHWESTERN UNIVERSITY · PI MACRENARIS, KEITH W · 2020 to 2024
$5.8M
Laser Ablation Inductively Coupled Plasma Time-of-Flight Mass Spectrometer for Advanced Bioelement Imaging ApplicationsS10OD026786 · OD · NORTHWESTERN UNIVERSITY · PI O'HALLORAN, THOMAS V · 2019 to 2019
$658k
Deciphering the relationship between bioresorbable magnesium alloy corrosion and the inflammatory microenvironment of the neotinimaR15HL167221 · NHLBI · MICHIGAN TECHNOLOGICAL UNIVERSITY · PI GUILLORY, ROGER J. · 2023 to 2023
$470k
NHLBI NIH HHS R15 HL167221NIGMS NIH HHS P41 GM135018NIH HHS S10 OD026786
6 · The paper itself

Abstract

While metal materials historically have served as permanent implants and were designed to avoid degradation, next generation bioabsorbable metals for medical devices such as vascular stents are under development, which would elute metal ions and corrosion byproducts into tissues. The fate of these eluted products and their local distribution in vascular tissue largely under studied. In this study, we employ a high spatial resolution spectrometric imaging modality, laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) to map the metal distribution, (herein refered to as laser ablation mapping, or LAM) from Mg alloys within the mouse vascular system and approximate their local concentrations. We used a novel rare earth element bearing Mg alloy (WE22) wire implanted within the abdominal aorta of transgenic hypercholesterolemic mice (APOE-/-) to simulate a bioabsorbable vascular prosthesis for up to 30 days. We describe qualitatively and semi-quantitatively implant-derived corrosion product presence throughout the tissue cross sections, and their approximate concentrations within the various vessel structures. Additionally, we report the spatial changes of corrosion products, which we postulate are mediated by phagocytic inflammatory cells such as macrophages (MΦ's).

Identifiers

PMID39386222
PMCPMC11462046

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.