Evidence map›Paper›PMID 39409256›Full record

ArticleSensors (Basel, Switzerland)2024

Design and Assembly of a Miniature Catheter Imaging System for In Vivo Heart Endoscopic Imaging.

Walter Messina, Lorenzo Niemitz, Simon Sorensen, Claire O'Dowling, Piotr Buszman, Stefan Andersson-Engels, Ray Burke

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Camera-on-tip endoscope forBiomedical optics express · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Walter MessinaBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.ORCID 0000-0001-5889-2660
Lorenzo NiemitzBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.ORCID 0000-0002-5261-7040
Simon SorensenBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.ORCID 0000-0003-3100-7152
Claire O'DowlingBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.
Piotr BuszmanCentre for Cardiovascular Research and Development of American Heart of Poland, 40-028 Katowice, Poland.
Stefan Andersson-EngelsBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.ORCID 0000-0001-5640-3122
Ray BurkeBiophotonics Group, Tyndall National Institute, University College Cork, T12 R5CP Cork, Ireland.

Funding

Science Foundation Ireland 22/RP-2TF/10293
6 · The paper itself

Abstract

In this paper, we present the design and fabrication of a novel chip-on-tip catheter, which uses a microcamera and optical fibres to capture in vivo images in a beating porcine heart thanks to a saline flush to clear the blood field. Here, we demonstrate the medical utility and mechanical robustness of this catheter platform system, which could be used for other optical diagnostic techniques, surgical guidance, and clinical navigation. We also discuss some of the challenges and system requirements associated with developing a miniature prototype for such a study and present assembly instructions. Methods of clearing the blood field are discussed, including an integrated flush channel at the distal end. This permits the capture of images of the endocardial walls. The device was navigated under fluoroscopic guiding, through a guiding catheter to various locations of the heart, where images were successfully acquired. Images were captured at the intra-atrial septum, in the left atrium after a trans-septal cross procedure, and in the left ventricle, which are, to the best of our knowledge, the first images captured in an in vivo beating heart using endoscopic techniques.

Indexed as

Cardiac CathetersEquipment DesignHeartAngioscopyAnimalsPrinting, Three-DimensionalSwinebiophotonicscardiovascular imagingcatheterisationmicrocameraprototyping

Identifiers

PMID39409256
PMCPMC11478442

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.