Evidence map›Paper›PMID 39423834›Full record

ArticleBiofabrication2024

Vascular smooth muscle cells can be circumferentially aligned inside a channel using tunable gelatin microribbons.

Yusuf Mastoor, Mahsa Karimi, Michael Sun, Fereshteh Ahadi, Pattie Mathieu, Mingyue Fan, Lin Han, Li-Hsin Han, Alisa Morss Clyne

Abstract read
In one paragraph

Article in Biofabrication, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yusuf MastoorFischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742, United States of America.ORCID 0000-0003-2760-9038
Mahsa KarimiDepartment of Mechanical Engineering and Mechanics, Drexel University, 3141 Chestnut St, Philadelphia, PA 19104, United States of America.ORCID 0000-0002-9833-9699
Michael SunFischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742, United States of America.ORCID 0000-0002-6998-3266
Fereshteh AhadiDepartment of Mechanical Engineering and Mechanics, Drexel University, 3141 Chestnut St, Philadelphia, PA 19104, United States of America.ORCID 0009-0003-6757-0331
Pattie MathieuFischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742, United States of America.
Mingyue FanSchool of Biomedical Engineering, Science and Health Systems, 3141 Chestnut St, Philadelphia, PA 19104, United States of America.ORCID 0000-0002-8365-7571
Lin HanSchool of Biomedical Engineering, Science and Health Systems, 3141 Chestnut St, Philadelphia, PA 19104, United States of America.ORCID 0000-0003-4180-1288
Li-Hsin HanDepartment of Mechanical Engineering and Mechanics, Drexel University, 3141 Chestnut St, Philadelphia, PA 19104, United States of America.ORCID 0000-0002-0135-2863
Alisa Morss ClyneFischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742, United States of America.ORCID 0000-0003-2462-2122

Funding

Artery-on-a-chip with perivascular adipose tissue for pressure myographyR21EB028466 · NIBIB · UNIV OF MARYLAND, COLLEGE PARK · PI MORSS CLYNE, ALISA S · 2019 to 2020
$415k
NIBIB NIH HHS R21 EB028466
6 · The paper itself

Abstract

The gold standard to measure arterial health is vasodilation in response to nitric oxide. Vasodilation is generally measured via pressure myography of arteries isolated from animal models. However, animal arteries can be difficult to obtain and may have limited relevance to human physiology. It is, therefore, critical to engineer human cell-based arterial models capable of contraction. Vascular smooth muscle cells (SMCs) must be circumferentially aligned around the vessel lumen to contract the vessel, which is challenging to achieve in a soft blood vessel model. In this study, we used gelatin microribbons to circumferentially align SMCs inside a hydrogel channel. To accomplish this, we created tunable gelatin microribbons of varying stiffnesses and thicknesses and assessed how SMCs aligned along them. We then wrapped soft, thick microribbons around a needle and encapsulated them in a gelatin methacryloyl hydrogel, forming a microribbon-lined channel. Finally, we seeded SMCs inside the channel and showed that they adhered best to fibronectin and circumferentially aligned in response to the microribbons. Together, these data show that tunable gelatin microribbons can be used to circumferentially align SMCs inside a channel. This technique can be used to create a human artery-on-a-chip to assess vasodilation via pressure myography, as well as to align other cell types for 3D

Indexed as

GelatinHydrogelsMuscle, Smooth, VascularMyocytes, Smooth MuscleAnimalsCells, CulturedHumansTissue EngineeringGelatinHydrogelsartery-on-a-chipcell alignmenthydrogelmicroribbonsvascular smooth muscle cells

Identifiers

PMID39423834
PMCPMC11583946

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.