Evidence map›Paper›PMID 39427079›Full record

ArticleScientific reports2024

Establishment of potential reference measurement procedure and reference materials for EML4-ALK fusion variants measurement.

Yi Yang, Yu Zhang, Shujun Zhou, Xia Wang, Chunyan Niu, Yongzhuo Zhang, Huafang Gao, Xiaohua Jin, Shangjun Wang, Meihong Du and 3 more

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Yi YangCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
Yu ZhangCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
Shujun ZhouShenzhen Institute for Technology Innovation, National Institute of Metrology, Shenzhen, 518107, China.
Xia WangCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
Chunyan NiuCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
Yongzhuo ZhangCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
Huafang GaoNational Research Institute for Family Planning, Beijing, 100081, China.
Xiaohua JinNational Research Institute for Family Planning, Beijing, 100081, China.
Shangjun WangNanjing Institute of Measurement and Testing Technology, Nanjing, 210049, Jiangsu, China.
Meihong DuInstitute of Analysis and Testing, Beijing Academy of Science and Technology (Beijing Center for Physical and Chemical Analysis), Beijing, 100094, China.
Xiaoyan ChengInstitute of Analysis and Testing, Beijing Academy of Science and Technology (Beijing Center for Physical and Chemical Analysis), Beijing, 100094, China.
Lingxiang ZhuTargetingOne Co., Ltd, Beijing, 102299, China.
Lianhua DongCenter for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China. donglh@nim.ac.cn.

Funding

National Key Research and Development Program of China 2023YFF0613300
6 · The paper itself

Abstract

Echinoderm microtubule-associated protein 4 (EML4) - anaplastic lymphoma kinase (ALK) fusion gene detection is of great significance in personalized tumor treatment. With the development of EML4-ALK fusion variants detection, it is necessary to establish traceability to ensure the consistency and comparability of its detection results in clinical practice. The establishment of traceability relies on SI traceable reference materials (RMs) and potential reference measurement procedures (RMPs). In this study, a potential RMP for the quantitative detection of V1 and V3 fusion mutations and the reference type (ALK-ref, including wild type, V1 and V3 mutant type) based on reverse transcription dPCR (RT-dPCR) and EML4-ALK fusion gene RMs were established. The proposed potential RMP has high specificity, good inter-laboratory reproducibility (CV < 7.3%) and good linear relationship (0.92 < slope < 1.06, R

Indexed as

Oncogene Proteins, FusionReference StandardsHumansLimit of DetectionMutationReproducibility of ResultsEML4-ALK fusion protein, humanOncogene Proteins, FusionEML4-ALKNon-small-cell lung cancerReference materials (RMs)Reference measurement procedure (RMP)Reverse transcription dPCR (RT-dPCR)

Identifiers

PMID39427079
PMCPMC11490547

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.