ArticleAnnals of biomedical engineering2025
An In vivo Pilot Study to Estimate the Swelling of the Aneurysm Wall Rabbit Model Generated with Pulsed Fluid Against the Aneurysm Wall.
Article in Annals of biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study addresses the critical issue of evaluating the risk of rupture of unruptured intracranial aneurysms (UIAs) through the assessment of the mechanical properties of the aneurysm wall. To achieve this, an original approach based on the development of an in vivo deformation device prototype (DDP) of the vascular wall is proposed. The DDP operates by pulsing a physiological fluid onto the vascular wall and measuring the resulting deformation using spectral photon counting computed tomography (SPCCT) imaging.
methodsIn this preliminary study conducted on a rabbit animal model, an aneurysm was induced on the carotid artery, followed by deformation of the aneurysm sac wall using the DDP. The change in luminal volume of the aneurysm sac induced by the deformation of the vascular wall was then quantified.
resultsThe initial experimental results demonstrated an increase in the luminal volume of the aneurysm sac in relation to the increased flow rate of the fluid pulsed by the DDP onto the arterial wall. Measurement of the pressure generated by the DDP in relation to the different flow rate values imposed by the pulsation system revealed experimental values of the same order of magnitude as dynamic blood pressure. Furthermore, theoretical pressure values on the deformed area, calculated using Euler's theorem, appeared to be correlated with experimental pressure measurements.
conclusionThis equivalence between theory and experiment is a key element in the use of the DDP for estimating the mechanical properties of the vascular wall, particularly for the use of finite element models to characterise the stress state of the deformed vascular wall. This preliminary work thus presents a novel, innovative, and promising approach for the evaluation and management of the risk of rupture of unruptured intracranial aneurysms.
Indexed as
Identifiers
39436612What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.