Observational studyBMJ open2024
Safety and performance of the ultrathin sirolimus-eluting coronary stent in an all-comer patient population: the S-FLEX UK-II registry.
Observational study in BMJ open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe evaluated the clinical safety and performance of the ultrathin strut biodegradable polymer-coated Supraflex Cruz (Sahajanand Medical TechnologiesLtd., Surat, India) sirolimus-eluting stent (SES) in an all-comer patient population requiring coronary stent implantation. STUDY
designThe study was a prospective, observational, multicentre, single-arm registry. STUDY SETTINGS: The study was conducted at 19 NHS Hospitals across the UK, from March 2020 to September 2021. STUDY
participantsA total of 1904 patients with symptomatic coronary artery disease (age ≥18 years) who underwent percutaneous coronary intervention with at least one Supraflex Cruz SES were enrolled. PRIMARY AND SECONDARY OUTCOMES MEASURE: The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI) and clinically indicated target lesion revascularisation (CI-TLR), at 12 months. Safety endpoints were stent thrombosis, all-cause death and any MI. Prespecified subgroups analysis included patients with diabetes mellitus, bifurcation lesion, type B2/C lesion defined as per ACC/AHA (American College of Cardiology/American Heart Association) lesion classification and long coronary lesions (>20 mm).
resultsA total of 2973 Supraflex Cruz SES were implanted in 1835 patients (mean age: 65.20±11.03 years). Of these, 404 patients had diabetes mellitus (491 lesions), 271 had bifurcation lesions (293 lesions), 1541 had type B2/C lesions (1832 lesions) and 985 had long coronary lesions (>20 mm, 1139 lesions). Among the overall population, device success was achieved in 98.2% of lesions. TLF occurred in 12 (0.7%) patients (0.3% cardiac death, 0.2% TV-MI, 0.2% CI-TLR) at 30 days and in 43 (2.3%) patients (0.8% cardiac death, 0.8% TV-MI, 0.8% CI-TLR) at 12 months follow-up. The rate of definite stent thrombosis was 0.3% in the overall population at 12 months. The incidence of TLF and stent thrombosis was 6.2% and 1% in the diabetic, 1.8% and none in bifurcation lesion, 2.5% and 0.3% in type B2/C lesion, and 2.7% and 0.3% in long coronary lesions (>20 mm) subgroups, respectively. at 12 months follow-up.
conclusionThe S-FLEX UK-II registry confirms the clinical safety and performance of the ultrathin Supraflex Cruz SES in an all-comer population with complex coronary artery disease, demonstrating low rates of TLF and stent thrombosis. TRIAL REGISTRATION NUMBER: ISRCTN39751665 (https://doi.org/10.1186/ISRCTN39751665).