Evidence map›Paper›PMID 39438097›Full record

Observational studyBMJ open2024

Safety and performance of the ultrathin sirolimus-eluting coronary stent in an all-comer patient population: the S-FLEX UK-II registry.

Vellore J Karthikeyan, Abdul Mozid, Suneil Aggarwal, Abhishek Kumar, David Hildick-Smith, Richard Anderson, Satheesh Nair, Neil Ruparelia, Nick Curzen, Murugu Veerasamy and 2 more

Abstract readObservational StudyMulticenter Study
In one paragraph

Observational study in BMJ open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Vellore J KarthikeyanDepartment of Cardiology, Wigan Hospital, Wigan, UK.
Abdul MozidDepartment of Cardiology, Leeds General Infirmary, Leeds, UK.
Suneil AggarwalDepartment of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK.
Abhishek KumarDepartment of Cardiology, Wigan Hospital, Wigan, UK.
David Hildick-SmithDepartment of Cardiology, Brighton and Sussex University Hospital, Brighton, UK.
Richard AndersonDepartment of Cardiology, University Hospital of Wales, Cardiff, UK.
Satheesh NairDepartment of Cardiology, Glan Clwyd Hospital, Rhyl, UK.
Neil RupareliaDepartment of Cardiology, Royal Berkshire Hospital, Reading, UK.
Nick CurzenDepartment of Cardiology, Southampton General Hospital, Southampton, UK.ORCID 0000-0001-9651-7829
Murugu VeerasamyDepartment of Cardiology, Leeds General Infirmary, Leeds, UK.
Sandra ElsheikhDepartment of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, UK.
Azfar ZamanDepartment of Cardiology, Freeman Hospital and Newcastle University, Newcastle upon Tyne, UK Azfar.Zaman@nhs.net.ORCID 0000-0003-4891-8892

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWe evaluated the clinical safety and performance of the ultrathin strut biodegradable polymer-coated Supraflex Cruz (Sahajanand Medical TechnologiesLtd., Surat, India) sirolimus-eluting stent (SES) in an all-comer patient population requiring coronary stent implantation. STUDY

designThe study was a prospective, observational, multicentre, single-arm registry. STUDY SETTINGS: The study was conducted at 19 NHS Hospitals across the UK, from March 2020 to September 2021. STUDY

participantsA total of 1904 patients with symptomatic coronary artery disease (age ≥18 years) who underwent percutaneous coronary intervention with at least one Supraflex Cruz SES were enrolled. PRIMARY AND SECONDARY OUTCOMES MEASURE: The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI) and clinically indicated target lesion revascularisation (CI-TLR), at 12 months. Safety endpoints were stent thrombosis, all-cause death and any MI. Prespecified subgroups analysis included patients with diabetes mellitus, bifurcation lesion, type B2/C lesion defined as per ACC/AHA (American College of Cardiology/American Heart Association) lesion classification and long coronary lesions (>20 mm).

resultsA total of 2973 Supraflex Cruz SES were implanted in 1835 patients (mean age: 65.20±11.03 years). Of these, 404 patients had diabetes mellitus (491 lesions), 271 had bifurcation lesions (293 lesions), 1541 had type B2/C lesions (1832 lesions) and 985 had long coronary lesions (>20 mm, 1139 lesions). Among the overall population, device success was achieved in 98.2% of lesions. TLF occurred in 12 (0.7%) patients (0.3% cardiac death, 0.2% TV-MI, 0.2% CI-TLR) at 30 days and in 43 (2.3%) patients (0.8% cardiac death, 0.8% TV-MI, 0.8% CI-TLR) at 12 months follow-up. The rate of definite stent thrombosis was 0.3% in the overall population at 12 months. The incidence of TLF and stent thrombosis was 6.2% and 1% in the diabetic, 1.8% and none in bifurcation lesion, 2.5% and 0.3% in type B2/C lesion, and 2.7% and 0.3% in long coronary lesions (>20 mm) subgroups, respectively. at 12 months follow-up.

conclusionThe S-FLEX UK-II registry confirms the clinical safety and performance of the ultrathin Supraflex Cruz SES in an all-comer population with complex coronary artery disease, demonstrating low rates of TLF and stent thrombosis. TRIAL REGISTRATION NUMBER: ISRCTN39751665 (https://doi.org/10.1186/ISRCTN39751665).

Indexed as

Coronary Artery DiseaseDrug-Eluting StentsProsthesis DesignSirolimusAgedFemaleHumansMaleMiddle AgedPercutaneous Coronary InterventionProspective StudiesRegistriesTreatment OutcomeUnited KingdomSirolimuscardiologycardiovascular diseasecoronary intervention

Identifiers

PMID39438097
PMCPMC11499841

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked