Comparative analysis of a novel spectral-domain OCT biometer versus swept-source OCT or OLCR biometer in healthy pediatric ocular biometry.

Wen Long, Alex Ong, Bingru Zheng, Ziqi Liang, Dongmei Cui

Abstract readComparative StudyObservational Study
In one paragraph

Observational study in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wen Long *Shenzhen Eye Hospital, Shenzhen Eye Institute, Jinan University, Shenzhen, China.
Alex Ong *Ong's Optics Myopia Management Centre, Singapore, Singapore.
Bingru ZhengShenzhen Eye Hospital, Shenzhen Eye Institute, Jinan University, Shenzhen, China.
Ziqi LiangShenzhen Eye Hospital, Shenzhen Eye Institute, Jinan University, Shenzhen, China.
Dongmei CuiShenzhen Eye Hospital, Shenzhen Eye Institute, Jinan University, Shenzhen, China. sarah72@126.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the advancements in ocular biometric technology, there have been significant improvements in accurately and efficiently measuring ocular parameters. The aim of this study is to compare the reliability of biometric parameters obtained using a new frequency-domain optical coherence tomography (SD-OCT) biometer with the measurements obtained from swept-source OCT (SS-OCT) and optical low coherence reflectometry (OLCR) biometers. This study employed an observational cross-sectional design. Measurements of axial length (AL), flat and steep corneal keratometry (K1 and K2), and central corneal thickness (CCT) obtained using the The Colombo IOL were compared with those obtained with the IOLMaster 700 and SW-9000 devices. The agreement were evaluated using intraclass correlation coefficient (ICC) and Bland-Altman analyses. The differences of the measurements of the three increments were assessed by one-way ANONA. 73 right eyes of 73 healthy pediatric subjects were analyzed. The AL difference measured by Colombo IOL compared with IOLmaster700 and SW-9000 were 0.00 ± 0.02 mm and - 0.07 ± 0.05 mm, respectively (P > 0.05, ANOVA). There was no statistically significant difference in CCT, K1, and K2 among the three instruments (all P > 0.05, ANOVA). The ICC values for AL, K1, K2, and CCT were 0.999, 0.996, 0.995, and 0.998, respectively. The Bland-Altman analysis showed an agreement of AL, K1, K2, and CCT with Colombo IOL and IOLMaster 700 spanned over 0.08 mm, 0.71D, 0.69D, and 12.17 μm, respectively. The agreement of AL, K1, K2, and CCT with Colombo IOL and SW-9000 spanned approximate 0.21 mm, 0.75D, 1.06D, and 14.37 μm, respectively. The new SD-OCT biometer and the SS-OCT biometer showed strong agreement in measuring AL and CCT in healthy pediatric subjects. This supports the reliability of the new SD-OCT biometer as an alternative for assessing these parameters. However, K1 and K2 could not be used interchangeably in clinical practice. Further research is needed to explore their applicability in different clinical settings and patient populations."light" />.

Indexed as

BiometryCorneaTomography, Optical CoherenceAdolescentAxial Length, EyeChildChild, PreschoolCross-Sectional StudiesFemaleHumansMaleReproducibility of ResultsColombo IOLIOLMaster 700SD-OCT optical biometerSS-OCT optical biometer

Identifiers

PMID39448792
PMCPMC11502762

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.