Prediction of Thrombus Formation within an Oxygenator via Bioimpedance Analysis.

Jan Korte, Tobias Lauwigi, Lisa Herzog, Alexander Theißen, Kai Suchorski, Lasse J Strudthoff, Jannis Focke, Sebastian V Jansen, Thomas Gries, Rolf Rossaint and 2 more

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Jan KorteDepartment of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.
Tobias LauwigiInstitut für Textiltechnik (ITA), RWTH Aachen University, 52074 Aachen, Germany.ORCID 0009-0009-8260-5321
Lisa HerzogInstitut für Textiltechnik (ITA), RWTH Aachen University, 52074 Aachen, Germany.
Alexander TheißenDepartment of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.
Kai SuchorskiInstitut für Textiltechnik (ITA), RWTH Aachen University, 52074 Aachen, Germany.
Lasse J StrudthoffDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-6810-6317
Jannis FockeDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-7846-584X
Sebastian V JansenDepartment of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-3808-9958
Thomas GriesInstitut für Textiltechnik (ITA), RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-2480-8333
Rolf RossaintDepartment of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.
Christian BleilevensDepartment of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.
Patrick WinnersbachDepartment of Anesthesiology, Medical Faculty, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany.ORCID 0000-0001-6979-6818

Funding

Deutsche Forschungsgemeinschaft DFG RO 2000/25-2RWTH Aachen University START-Program
6 · The paper itself

Abstract

Blood clot formation inside the membrane oxygenator (MO) remains a risk in extracorporeal membrane oxygenation (ECMO). It is associated with thromboembolic complications and normally detectable only at an advanced stage. Established clinical monitoring techniques lack predictive capabilities, emphasizing the need for refinement in MO monitoring towards an early warning system. In this study, an MO was modified by integrating four sensor fibers in the middle of the hollow fiber mat bundle, allowing for bioimpedance measurement within the MO. The modified MO was perfused with human blood in an

Indexed as

Electric ImpedanceThrombosisBiosensing TechniquesExtracorporeal Membrane OxygenationHumansOxygenators, Membranebioimpedance analysisclot detectioncoagulationECLSECMOmembrane oxygenatorRatOxsensor fibers

Identifiers

PMID39451724
PMCPMC11506726

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.