Evidence map›Paper›PMID 39472595›Full record

ArticleScientific reports2024

Miniaturized circularly polarized wearable array antenna for medical device applications.

Muammer Omran, Changiz Ghobadi, Javad Nourinia, Majid Shokri

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Muammer OmranDepartment of Electrical Engineering, Urmia University, Urmia, Iran.
Changiz GhobadiDepartment of Electrical Engineering, Urmia University, Urmia, Iran. ch.ghobadi@urmia.ac.ir.
Javad NouriniaDepartment of Electrical Engineering, Urmia University, Urmia, Iran.
Majid ShokriDepartment of Electrical Engineering, Urmia University, Urmia, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Antenna miniaturization is essential for healthcare applications, and numerous studies have tackled the challenge of presenting miniaturized, reliable designs while maintaining performance. This paper presents a small circularly polarized (CP) sequential wearable array antenna with overall dimensions of only 110 mm × 95 mm × 1.8 mm. It comprises four novel designs of circular-shaped elements arranged sequentially in an array configuration measured only 24 mm×24 mm×1 mm. It is fed by a separate cascade feeding network incorporating a single rat-race and two branch-line couplers. The antenna is designed for medical device applications within the 2.4 GHz Industrial Scientific Medical (ISM) frequency band. The proposed design is fabricated and experimentally tested, demonstrating wide impedance bandwidths of 21.24% (2.2-2.72 GHz) and an Axial Ratio (AR) bandwidth (AR < 3 dB) covering the entire 2.4 GHz ISM frequency band. At 2.43 GHz, the antenna achieves a gain of -14.9 dBi. Both simulation and experimental results confirm excellent performance in impedance matching, gain pattern, and circular polarization, making it promising for wearable wireless communication in medical applications. The link margin was calculated, and the specific absorption rate of the antenna was analyzed, the result revealing that it aligns with the safety limits of IEEE C95.1-1999 standards.

Indexed as

Equipment DesignMiniaturizationWearable Electronic DevicesWireless TechnologyHumansArray antennaCircular polarizationISM bandMedical applicationPatch antennaSequential-phase feed network