Evidence map›Paper›PMID 39499689›Full record

ArticlePloS one2024

Flow characterization and structural alterations in Ahmed glaucoma FP7 tubes after in-vitro aging in silicone oil.

Abu Tahir Taha, Matthew Clarke, Chiara Wabl, Ying Han, Frank Brodie

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abu Tahir TahaDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, United States of America.ORCID 0009-0005-0486-4636
Matthew ClarkeForSight VISION6 Inc, Brisbane, CA, United States of America.
Chiara WablDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, United States of America.
Ying HanDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, United States of America.
Frank BrodieDepartment of Ophthalmology, University of California San Francisco, San Francisco, CA, United States of America.ORCID 0000-0002-6908-6557

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePatients with intraocular silicone oil (SO) display higher odds of surgical failure after Ahmed glaucoma valve (AGV) implantation compared to patients without SO. However, the structural impact of SO exposure on silicone-made AGV tubes and the resulting changes in flow rate remain unexplored. This in-vitro study evaluated changes in tube dimensions and flow rates of AGV FP7 tubes after SO exposure to inform clinicians how such changes may impact AGV functionality.

methodsAGV FP7 tube segments underwent accelerated aging to approximate 90 days of exposure to the following media: Balanced Salt Solution (BSS), 1000 centistokes (cs) SO, and 5000cs SO. Tube dimensions were measured before and after aging. A constant gravity flow test setup was created to measure flow rates through tubes before and after aging. The students' T-test was used to compare the mean change between groups post-aging.

resultsPost-exposure, 1000cs and 5000cs SO tube segments increased in length by 5.94% and 5.55%, respectively, compared to 0.38% of BSS tubes (P < 0.05 for both). The inner lumen area expanded for tube segments in 1000cs and 5000cs SO by 11.75% and 2.70%, respectively, but contracted for tubes in BSS by -2.70% (P < 0.01 and P = 0.068 for 1000cs and 5000cs SO, respectively). Post aging, the flow rates increased on average by 61.0% and 98.6% for 1000cs and 5000cs SO, respectively, whereas flow rates for BSS tube segments slightly decreased by -4.92%. The difference was statistically significant for BSS vs. SO groups (P < 0.01 for both).

conclusionsProlonged exposure to SO structurally altered the AGV FP7 tube segments by expanding their cross-sectional area, potentially leading to increased flow rates. These results may inform clinicians about potential in-vivo interactions in patients with the simultaneous presence of glaucoma drainage devices and intraocular SO.

Indexed as

Glaucoma Drainage ImplantsSilicone OilsGlaucomaHumansSilicone Oils

Identifiers

PMID39499689
PMCPMC11537406

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.