ArticleObesity surgery2024
Survey of Bariatric Surgeon Calibration Tube Use in Sleeve Gastrectomy.
Article in Obesity surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Fluorescence-guided sleeve gastrectomy and gastric bypass: first-in-human trial using novel gastric calibration tube.Surgical endoscopy · 2025Trial
- Beyond the Procedure: Revisiting the Technical Determinants of Sleeve Gastrectomy and Roux-en-Y Gastric Bypass.Journal of metabolic and bariatric surgery · 2026Review
- "Mini," "Midi," and "Super" Sleeves: Clarifying Misleading Labels in Sleeve Gastrectomy.Obesity surgery · 2025Article
- Laparoscopic Roux-en-Y Gastric Bypass Using a Fluorescence-Guided Gastric Calibration Tube.CRSLS : MIS case reports from SLSArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeThe study objective was to identify variations in calibration tube use during sleeve gastrectomy and understand elements of ideal calibration tube performance. MATERIALS AND
methodsA survey was distributed via email and social media to bariatric surgeons, who were asked to rate the performance of their current calibration tube and an ideal calibration tube for five technical milestones involving visualization, positioning, suction capability, and sleeve sizing. Data was analyzed using descriptive and bivariate analyses including chi-square, Mann-Whitney, and Kruskal-Wallis tests.
resultsAfter eliminating incorrect screening question responses, 552 of 585 responses were analyzed. Demographics included 82% practicing in the USA, 64% in community practice, performing an average of 114 (SD = 94.5) sleeves annually. Calibration tubes used were most commonly reusable (54.2%) versus disposable (27.4%), endoscope (5.3%), or other (13.2%). Ninety-six percent of calibration tube sizes were 32 to 44 French. The reusable calibration tube had the lowest mean scores in all five technical areas, while the endoscope performed the best. When comparing surgeon current to ideal calibration tube performance, the endoscope performed closest to an ideal device, with significant p-values for technical milestones (i-iv). Despite the endoscope having the highest ratings for technical performance, surgeons rated higher satisfaction using disposable calibration tubes.
conclusionSignificant variation exists among the size and type of calibration tubes used for sleeve gastrectomy. Calibration tubes incorporating the visualization of an endoscope with the workflow of a disposable device could bridge technical performance and satisfaction goals for surgeons.
Indexed as
Identifiers
39548023What Socratic holds
Registered trials