Evidence map›Paper›PMID 39592676›Full record

ArticleScientific reports2024

Calculation of vessel pulse wave velocities in retinal vein segments within the optic disc centre.

A Vukmirovic, W H Morgan, D Obreschkow, A Abdul-Rahman, D Y Yu, A Mehnert

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Quantifying Lateral Pulsation in Retinal Vessels Within the Optic Disc.Translational vision science & technology · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

A VukmirovicLions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Crawley, Australia. aleksandar.vukmirovic@lei.org.au.
W H MorganLions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Crawley, Australia.
D ObreschkowInternational Centre for Radio Astronomy Research (ICRAR), M468, University of Western Australia, 35 Stirling Hwy, Crawley, WA, 6009, Australia.
A Abdul-RahmanLions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Crawley, Australia.
D Y YuLions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Crawley, Australia.
A MehnertLions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Crawley, Australia.

Funding

National Health and Medical Research Council APP1162615
6 · The paper itself

Abstract

The carotid-femoral pulse wave velocity (PWV) method is used clinically to determine degrees of stiffness and other indices of disease. It is believed PWV measurement in retinal vessels may allow early detection of diseases. In this paper we present a new non-invasive method for estimating PWVs in retinal vein segments close to the optic disc centre, based on the measurement of blood column pulsation in retinal veins (reflective of vessel wall pulsation), using modified photoplethysmography (PPG). An optic disc (OD) PPG video is acquired spanning three cardiac cycles for a fixed ophthalmodynamometric force. The green colour channel frames are extracted, cropped and aligned. A harmonic regression model is fitted to each pixel intensity time series along the vein centreline from the centre to the periphery of the OD. The phase of the first harmonic is plotted against centreline distance. A least squares line is fitted between the first local maximum phase and first local minimum phase and its slope used to compute PWV. Five left eye inferior hemi-retinal veins from five healthy subjects were analysed. Velocities were calculated for several induced intraocular pressures ranging from a mean baseline of 14 mmHg (SD 5) to 56 mmHg in steps of approximately 5 mmHg. The median PWV over all pressure steps and subjects was 20.77 mm/s (IQR 29.27). The experimental results show that pulse wave propagation direction was opposite to flow in this initial venous segment.

Indexed as

Optic DiskPulse Wave AnalysisRetinal VeinAdultBlood Flow VelocityFemaleHumansIntraocular PressureMalePhotoplethysmography

Identifiers

PMID39592676
PMCPMC11599586

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked