Evidence map›Paper›PMID 39592943›Full record

ArticleBMC anesthesiology2024

Motion resistance in peripheral oxygen saturation monitoring using Biolight Analog SpO

Ting Yang, Yong Liu, FengHua Cai, Yong Li, Muhammad Saqib Mudabbar

Abstract readComparative Study
In one paragraph

Article in BMC anesthesiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ting YangDepartment of Anesthesiology, Affiliated Hospital of Southwest Jiaotong University, The Third People's Hospital of Chengdu, Chengdu, Sichuan, 610014, China.
Yong LiuDepartment of Clinical Applications, Guangdong Biolight Meditech Co., Ltd., No.2 Innovation 1st Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, Guangdong, 519085, China.
FengHua CaiDepartment of Clinical Applications, Guangdong Biolight Meditech Co., Ltd., No.2 Innovation 1st Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, Guangdong, 519085, China.
Yong LiDepartment of Electronics Engineering, Heilongjiang University, No.74, Xuefu Road, Nangang District, Harbin City, Heilongjiang province, 150080, China.
Muhammad Saqib MudabbarDepartment of Clinical Applications, Guangdong Biolight Meditech Co., Ltd., No.2 Innovation 1st Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, Guangdong, 519085, China. saqibmudabbar@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPulse oximeters are vital for assessing blood oxygen levels but can produce inaccurate readings during patient motion, leading to false alarms and alarm fatigue. Analog SpO

methodsThirty healthy adults underwent controlled experiments (Control, Linear Motion, Angular Motion) using two pulse oximeters. Linear Motion tested hand displacement impact, while Angular Motion involved rhythmic hand motions at 120 bpm and 160 bpm.

resultsBoth devices performed similarly in Control, with no disruptions. In Linear Motion, mild disruptions occurred, but no significant differences in SpO

conclusionsAnalog SpO

trial registrationThe study was submitted to and approved by the Biolight Ethics Committee (S0723), and written informed consent from all participants was obtained.

Indexed as

OximetryOxygen SaturationAdultClinical AlarmsFemaleHumansMaleMotionYoung AdultAccuracyAlarmsAnalog SpO2Healthy adultsMonitoringMotion resistance“Oximetry/instrumentation”[Mesh]Pulse oximetry

Identifiers

PMID39592943
PMCPMC11600824

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.