ArticleHeliyon2024
M-fiducial phantom based fast automatic ultrasound calibration technique: A novel approach for 2D to 3D image registration.
Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Multimodal CT-ultrasound image-guided robotic system for automated abdominal puncture.Journal of robotic surgery · 2026Article
- A Novel Shape-Prior-Guided Automatic Calibration Method for Free-Hand Three-Dimensional Ultrasonography.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study introduces a novel M-fiducial phantom-based automatic ultrasound (US) calibration technique aimed at improving 2D to 3D image registration in ultrasound-guided procedures. The technique addresses limitations in existing methods by enhancing feature extraction capabilities and improving calibration accuracy. The proposed method utilizes an M-fiducial phantom, an extended version of the standard N-fiducial phantom, designed to facilitate automatic extraction with a linear probe, particularly in small field-of-view scenarios. A closed-form solution incorporating anisotropic scaling enables rapid and precise computation of transformation matrices for ultrasound calibration, and the method was tested across varying ultrasound depths to evaluate performance in point localization, length measurement, and volume estimation. Results show that the automatic extraction method, combined with the anisotropic closed-form solution, offers greater accuracy and reliability compared to manual methods. While in-plane measurements demonstrated high accuracy, out-plane estimations revealed potential limitations, especially with wire phantoms at increased depths. Despite these challenges, the M-fiducial phantom-based technique reduces operator workload and enhances ultrasound calibration precision, making it a promising approach for high-precision ultrasound-guided interventions. Future work should focus on refining the technique and validating its efficacy in clinical applications.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.