Evidence map›Paper›PMID 39640198›Full record

ArticleFrontiers in surgery2024

Evaluation of the patency rate and endothelialization of a poly-ε-caprolactone, nanofiber sheet-based vascular graft using a rat abdominal aortic implantation model.

Yuta Kikuchi, Naohiro Wakabayashi, Daikelly I Braghirolli, Patricia Pranke, Hiroyuki Kamiya, Kyohei Oyama

Abstract read
In one paragraph

Article in Frontiers in surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuta Kikuchi *Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Japan.
Naohiro Wakabayashi *Sapporo Cardiovascular Clinic, Department of Cardiovascular Surgery, Sapporo, Japan.
Daikelly I BraghirolliHematology and Stem Cell Laboratory, Faculty of Pharmacy, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, Brazil.
Patricia PrankeHematology and Stem Cell Laboratory, Faculty of Pharmacy, Universidade Federal Do Rio Grande Do Sul, Porto Alegre, Brazil.
Hiroyuki KamiyaDepartment of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Japan.
Kyohei OyamaDepartment of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: The global increase in cardiovascular diseases has resulted in an augmented development of artificial small-caliber vascular grafts used in bypass graft surgeries, such as coronary and distal artery bypass graft surgeries. However, no consensus exists regarding the best method for creating vascular grafts. Poly-ε-caprolactone (PCL) is a biocompatible and biodegradable material that has been widely studied as a scaffold for tissue regeneration, inclusive of vascular grafts. In this study, a vascular graft was created from a PCL nanofiber sheet (PCL graft), and the performance thereof was examined using a rat abdominal aortic implantation model. Methods: The PCL nanofiber sheets were created using an electrospinning machine. These nanofiber sheets were rolled up. Glue was applied between layers using a PCL solution to create a PCL nanofiber vascular graft, with an inner diameter of 1 mm. PCL grafts with 7 mm length were implanted into the abdominal aorta of rats. Thereafter, the patency was determined by pulsating blood flow from the hemiresection site of the distal aorta of the graft anastomosis, and endothelialization was examined using hematoxylin and eosin and immunofluorescent staining methods. Results: The patency rate of the PCL graft at 2 weeks was 57.1% (12 of 21 cases), which is not satisfactory as a small-caliber vascular graft. Patent cases, however, revealed a CD31-positive endothelial cell layer in the inner lumen and autologous cell infiltration into the scaffold, indicating autologous vessel-like regeneration. By contrast, the occluded cases showed disassembly of the nanofiber layers; and the inner layers folded into the middle of the lumen. This observation suggested that the disassembled inner layer of the PCL graft disturbed the blood flow and triggered occlusion. Conclusions: PCL grafts can exhibit autologous vessel-like regeneration; nonetheless, regarding patency, grafts made from rolled-up PCL nanofiber sheets have structural weaknesses. Further improvements are required to achieve a long-term and high patency rate for PCL grafts.

Indexed as

electrospinningendothelializationnanofiberpoly-ε-caprolactonevascular graft

Identifiers

PMID39640198
PMCPMC11617548

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.