Evidence map›Paper›PMID 39661605›Full record

ArticlePloS one2024

Power analysis for personal light exposure measurements and interventions.

Johannes Zauner, Ljiljana Udovicic, Manuel Spitschan

Erratum issuedAbstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Johannes ZaunerDepartment Health and Sports Sciences, Technical University of Munich, TUM School of Medicine and Health, Chronobiology & Health, Munich, Germany.ORCID 0000-0003-2171-4566
Ljiljana UdovicicFederal Institute for Occupational Safety and Health (BAuA), Dortmund, Germany.ORCID 0000-0002-6035-8309
Manuel SpitschanDepartment Health and Sports Sciences, Technical University of Munich, TUM School of Medicine and Health, Chronobiology & Health, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLight exposure regulates the human circadian system and more widely affects health, well-being, and performance. With the rise in field studies on light exposure's effects, the amount of data collected through wearable loggers and dosimeters has also grown. These data are more complex than stationary laboratory measurements. Determining sample sizes in field studies is challenging, as the literature shows a wide range of sample sizes (between 2 and 1,887 from a recent review of the field and approaching 105 participants in first studies using large-scale 'biobank' databases). Current decisions on sample size for light exposure data collection lack a specific basis rooted in power analysis. Therefore, there is a need for clear guidance on selecting sample sizes.

methodsHere, we introduce a novel procedure based on hierarchical bootstrapping for calculating statistical power and required sample size for wearable light and optical radiation logging data and derived summary metrics, taking into account the hierarchical data structure (mixed-effects model) through stepwise resampling. Alongside this method, we publish a dataset that serves as one possible basis to perform these calculations: one week of continuous data in winter and summer, respectively, for 13 early-day shift-work participants (collected in Dortmund, Germany; lat. 51.514° N, lon. 7.468° E).

resultsApplying our method on the dataset for twelve different summary metrics (luminous exposure, geometric mean, and standard deviation, timing/time above/below threshold, mean/midpoint of darkest/brightest hours, intradaily variability) with a target comparison across winter and summer, reveals required sample sizes ranging from as few as 3 to more than 50. About half of the metrics-those that focus on the bright time of day-showed sufficient power already with the smallest sample. In contrast, metrics centered around the dark time of the day and daily patterns required higher sample sizes: mean timing of light below mel EDI of 10 lux (5), intradaily variability (17), mean of darkest 5 hours (24), and mean timing of light above mel EDI of 250 lux (45). The geometric standard deviation and the midpoint of the darkest 5 hours lacked sufficient power within the tested sample size.

conclusionsOur novel method provides an effective technique for estimating sample size in light exposure studies. It is specific to the used light exposure or dosimetry metric and the effect size inherent in the light exposure data at the basis of the bootstrap. Notably, the method goes beyond typical implementations of bootstrapping to appropriately address the structure of the data. It can be applied to other datasets, enabling comparisons across scenarios beyond seasonal differences and activity patterns. With an ever-growing pool of data from the emerging literature, the utility of this method will increase and provide a solid statistical basis for the selection of sample sizes.

Indexed as

LightAdultCircadian RhythmFemaleHumansMaleSample SizeSeasonsWearable Electronic Devices

Identifiers

PMID39661605
PMCPMC11633969

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.