Evidence map›Paper›PMID 39688518›Full record

ArticleVeterinary medicine and science2025

Evaluation of the Accuracy of FreeStyle Libre 2 for Glucose Monitoring in White New Zealand Rabbits.

Minseok Choi, Yeon Chae, Jayeon Park, Yelim Lee, Kyung-Mee Park, Dong-Hyuk Jeong, Byeong-Teck Kang, Taesik Yun, Hakhyun Kim

Abstract readEvaluation Study
In one paragraph

Article in Veterinary medicine and science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Minseok ChoiLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-5936-8956
Yeon ChaeLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-9816-6900
Jayeon ParkLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0001-5085-8281
Yelim LeeLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-6902-0849
Kyung-Mee ParkLaboratory of Surgery/Ophthalmology, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-7165-6731
Dong-Hyuk JeongLaboratory of Wildlife Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0001-7604-5721
Byeong-Teck KangLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-4471-4342
Taesik YunLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0003-1372-4430
Hakhyun KimLaboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Chungbuk National University, Cheongju, Chungbuk, South Korea.ORCID 0000-0002-8882-2329

Funding

National Research Foundation (NRF) of Korea 2022R1A4A1025557
6 · The paper itself

Abstract

backgroundStudies are currently being conducted on rabbits requiring serial glucose monitoring. The FreeStyle Libre 2 (FSL2), a serial glucose monitoring device, has been validated in humans, dogs and cats, but not in rabbits.

objectivesThis study aimed to evaluate the accuracy of the FSL2 in rabbits.

methodsSix healthy rabbits were used in this study. Interstitial glucose (IG) was measured using the FSL2, and blood glucose (BG) was measured using a portable blood glucose meter (PBGM); their results were compared with those from a clinical chemistry analyser. For the first 3 h, IG and BG were measured at 1-h intervals. Subsequently, they were measured every 8 h over a 48-h period. Regular insulin 0.2 U/kg was then administered to the rabbits, and IG and BG were measured every 15 min over a 90-min period.

resultsBefore insulin treatment, no measurements fell within the hypoglycaemic range (BG < 100 mg/dL). In the euglycaemic range (BG ≥ 100 mg/dL), the PBGM and FSL2 showed 85.7% and 23.8% accuracies, respectively. After insulin treatment, the PBGM showed 95.5% and 81.3% accuracies in the hypoglycaemic and euglycaemic ranges, respectively. The FSL2 showed 68.1% and 37.5% accuracies in the hypoglycaemic and euglycaemic ranges, respectively. Parkes consensus error grid analysis showed that the PBGM and FSL2 had 100% agreement for Zones A (no effect on clinical action) and B (altered clinical action unlikely to affect outcome) in rabbits with and without insulin treatment.

conclusionsThere was limited agreement between the FSL2 and reference standard BG measurements. However, the FSL2 allows clinically acceptable identification of hypoglycaemic states in rabbits.

Indexed as

Blood GlucoseAnimalsBlood Glucose Self-MonitoringFemaleMaleRabbitsBlood GlucoseFreeStyle Libre 2FSL2hypoglycaemiainterstitial glucoserabbit

Identifiers

PMID39688518
PMCPMC11651090

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.