Evidence mapPaperPMID 39696289Full record

ArticleBMC biotechnology2024

Development of a thrombin-antithrombin complex detection kit and study in venous thromboembolism complicated by cervical cancer.

Yanru Qiu, Shuang Han, Yu Ji, Zhixian Lu, Xuan Huang

Abstract read
In one paragraph

Article in BMC biotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Hemostasis at the edge between physiology and cancer.Internal and emergency medicine · 2026
    Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Coagulation Markers and Myocardial Blush Grade in STEMI: Identifying Potential Predictors of Microvascular Reperfusion.Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yanru Qiu *Department of Laboratory Medicine, Jiangnan University Hospital, Jiangsu Province, 1000 Hefeng Road, Wuxi City, 214122, No, China.
Shuang Han *Department of Pathology, Jiangnan University Hospital, Wuxi, Jiangsu, China.
Yu JiDepartment of Pathology, Jiangnan University Hospital, Wuxi, Jiangsu, China.
Zhixian LuDepartment of Laboratory Medicine, Jiangnan University Hospital, Jiangsu Province, 1000 Hefeng Road, Wuxi City, 214122, No, China. seed001lzx@163.com.
Xuan HuangDepartment of Laboratory Medicine, Jiangnan University Hospital, Jiangsu Province, 1000 Hefeng Road, Wuxi City, 214122, No, China. xghx.2007@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveOur study successfully developed an assay kit for thrombin-antithrombin complex (TAT) and demonstrated the predictive value of plasma TAT concentration in the development of venous thromboembolism (VTE) in patients with cervical cancer.

methodA retrospective analysis was conducted on 177 patients with cervical cancer who received treatment at the Affiliated Hospital of Jiangnan University in Wuxi City from July 1, 2023 to October 1, 2023. This study provides a comprehensive analysis of cervical cancer patients and their VTE risk factors. The patients were divided into two groups: 27 cases with VTE (Thrombosis group) and 150 cases without VTE (Non-thrombotic group). Additionally, the patients were classified into four stages based on tumor stage: 42 cases of stage I, 45 cases of stage II, 62 cases of stage III, and 28 cases of stage IV. The control group consisted of 80 healthy patients undergoing medical check-ups. Thrombin-antithrombin complex (TAT), fibrinolytic enzyme-α2-fibrinolytic inhibitor complex (PIC), thrombomodulin (TM), and tissue-type plasminogen activator inhibitor 1 complex (t-PAIC) were detected using quantitative chemiluminescence immunoassay. The study assessed the variations in thrombotic marker levels among cervical cancer patients of different stages through a receiver operating characteristic (ROC) curve.

resultThe TAT reagent demonstrated a detection limit of 0.048 ng/mL, with a linear R value of 0.9997, indicating high accuracy and precision. The reagent's accelerated stability was also excellent, with deviations of less than 10%. Furthermore, the correlation coefficient of this method with Hyson Mecon was R

conclusionOur developed TAT test kit has excellent performance and low cost, making it a clinically valuable tool for widespread use. Elevated TAT levels have significant predictive value for thrombosis occurrence in cervical cancer patients. The combination of t-PAIC, TM, TAT, PIC, D-dimer(D-D), and FDP markers is superior to using a single marker for diagnosing VTE in patients with malignant tumors. Screening cervical cancer patients for the six markers is essential to aid in active prophylaxis, determine optimal treatment timing, and implement nursing interventions to improve prognosis, reduce venous thrombosis incidence and mortality, and prolong survival time.

Indexed as

Antithrombin IIIPeptide HydrolasesUterine Cervical NeoplasmsVenous ThromboembolismAdultAgedFemaleHumansMiddle AgedReagent Kits, DiagnosticRetrospective StudiesAntithrombin IIIantithrombin III-protease complexPeptide HydrolasesReagent Kits, DiagnosticCervical cancerChemiluminescence kit developmentThrombin-antithrombin III complexThrombosis markersVenous thromboembolism

Identifiers

PMID39696289
PMCPMC11653829

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.