A multimodal axial array resonator and its application in radiofrequency (RF) volume coil designs for low-field open magnetic resonance imaging (MRI).

Yunkun Zhao, Aditya A Bhosale, Xiaoliang Zhang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Circuit design for broadband decoupling in multi-coil multi-nuclear applications.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yunkun ZhaoDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, USA.ORCID https://orcid.org/0009-0006-2859-4500
Aditya A BhosaleDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, USA.
Xiaoliang ZhangDepartment of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, USA.

Funding

Enhanced MR for morphological characterization of ligaments, tendons and boneU01EB023829 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LI, XIAOJUAN, ZHANG, XIAOLIANG · 2018 to 2024
$1.9M
NIBIB NIH HHS U01 EB023829
6 · The paper itself

Abstract

Background: Low-field open magnetic resonance imaging (MRI) systems, typically operating at magnetic field strengths below 1 Tesla, has greatly expanded the accessibility of MRI technology to meet a wide range of patient needs. However, the inherent challenges of low-field MRI, such as limited signal-to-noise ratios and limited availability of dedicated radiofrequency (RF) coils, have prompted the need for innovative coil designs that can improve imaging quality and diagnostic capabilities. In this work, we introduce a multimodal axial array resonator and its implementation in a volume coil, or referred to as a coupled stack-up volume coil, to address these challenges in low-field open MRI. Methods: A prototype coupled stack-up volume coil was designed with optimized coil spacing to improve B1 field homogeneity. Finite difference time-domain (FDTD) simulations were conducted to evaluate the coil's performance, including B1 field efficiency and specific absorption rate (SAR). Bench tests were performed to validate the simulated results using oil phantoms. Comparisons were made with a solenoid coil, a birdcage coil, and an equal gap coupled coil throughout the study. Results: Numeral electromagnetic studies demonstrate the superior performance of the proposed coupled stack-up volume coil, achieving 47.7% higher transmit/receive efficiency and 68% more uniform magnetic field distribution compared to conventional birdcage coils. The results of the bench tests show that the achieved B1 field efficiency of the coupled stack-up volume coil is 11.48 Conclusions: A multimodal axial array resonator technique or coupled stack-up technique is successfully developed for the design of low field MR RF volume coils. The proposed coupled stack-up volume coil outperforms the conventional volume coils in terms of B1 efficiency, imaging coverage, and low-frequency operation capability. This design provides a robust and simple solution to the low-field MR RF coil design.

Indexed as

head magnetic resonance imaging (head MRI)multimodal RF coilRadiofrequency coil (RF coil)stack-up coilvolume coil

Identifiers

PMID39698693
PMCPMC11651965

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.