Evidence map›Paper›PMID 39714084›Full record

SynthesisJournal of medical Internet research2024

Tracking Upper Limb Motion via Wearable Solutions: Systematic Review of Research From 2011 to 2023.

Eirini Karoulla, Maria Matsangidou, Fotos Frangoudes, Panayiotis Paspalides, Kleanthis Neokleous, Constantinos S Pattichis

Abstract readSystematic Review
In one paragraph

Synthesis in Journal of medical Internet research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Eirini KaroullaCEA-List, Université Paris-Saclay, Gif-sur-Yvette, France.ORCID 0009-0008-6624-5744
Maria MatsangidouCYENS - Centre of Excellence, Nicosia, Cyprus.ORCID 0000-0003-3804-5565
Fotos FrangoudesCYENS - Centre of Excellence, Nicosia, Cyprus.ORCID 0000-0002-2543-8194
Panayiotis PaspalidesCYENS - Centre of Excellence, Nicosia, Cyprus.ORCID 0009-0009-5661-6895
Kleanthis NeokleousCYENS - Centre of Excellence, Nicosia, Cyprus.ORCID 0000-0003-4773-9665
Constantinos S PattichisCYENS - Centre of Excellence, Nicosia, Cyprus.ORCID 0000-0003-1271-8151

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe development of wearable solutions for tracking upper limb motion has gained research interest over the past decade. This paper provides a systematic review of related research on the type, feasibility, signal processing techniques, and feedback of wearable systems for tracking upper limb motion, mostly in rehabilitation applications, to understand and monitor human movement.

objectiveThe aim of this article is to investigate how wearables are used to capture upper limb functions, especially related to clinical and rehabilitation applications.

methodsA systematic literature search identified 27 relevant studies published in English from 2011 to 2023, across 4 databases: ACM Digital Library, IEEE Xplore, PubMed, and ScienceDirect. We included papers focusing on motion or posture tracking for the upper limbs, wearable devices, feedback given to end users, and systems having clinical or rehabilitation purposes. We excluded papers focusing on exoskeletons, robotics, prosthetics, orthoses, or activity recognition systems; reviews; and books.

resultsThe results from this research focus on wearable devices that are designed to monitor upper limb movement. More specifically, studies were divided into 2 distinct categories: clinical motion tracking (15/27, 56%) and rehabilitation (12/27, 44%), involving healthy individuals and patients, with a total of 439 participants. Among the 27 studies, the majority (19/27) used inertial measurement units to track upper limb movement or smart textiles embedded with sensors. These devices were attached to the body with straps (mostly Velcro), providing flexibility and stability. The developed wearable devices positively influenced user motivation through the provided feedback, with visual feedback being the most common owing to the high level of independence provided. Moreover, a variety of signal processing techniques, such as Kalman and Butterworth filters, were applied to ensure data accuracy. However, limitations persist and include sensor positioning, calibration, and battery life, as well as a lack of clinical data on the effectiveness of these systems. The sampling rate of the data collection ranged from 50 Hz to 2000 Hz, which notably affected data quality and battery life. In addition, several findings were inconclusive, and thus, further future research is needed to understand and improve upper limb posture to develop progressive wearable systems.

conclusionsThis paper offers a comprehensive overview of wearable monitoring systems, with a focus on upper limb motion tracking and rehabilitation. It emphasizes the various types of available solutions; their efficacy, wearability, and feasibility; and proposed processing techniques. Finally, it presents robust findings regarding feedback accuracy derived from experiments and outlines potential future research directions.

Indexed as

MovementUpper ExtremityWearable Electronic DevicesHumansinteractive feedbackmotion sensingmotion trackingposture monitoringreal-time feedbackupper limb motionupper limb rehabilitationwearable deviceswearble technology

Identifiers

PMID39714084
PMCPMC11704657

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.