Evidence map›Paper›PMID 39738434›Full record

ArticleScientific reports2024

A multi-channel bioimpedance-based device for Vietnamese hand gesture recognition.

Nhat-Minh Than, Son-Thuy Nguyen, Dang-Nguyen Huynh, Thao-Nguyen Tran, Nguyen-Khoa Le, Huu-Xuan Mai, Cao-Dang Le, Tan-Thi Pham, Quang-Linh Huynh, Trung-Hau Nguyen

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Nhat-Minh ThanDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Son-Thuy NguyenDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Dang-Nguyen HuynhDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Thao-Nguyen TranDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Nguyen-Khoa LeDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Huu-Xuan MaiDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Cao-Dang LeDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Tan-Thi PhamDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Quang-Linh HuynhDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam.
Trung-Hau NguyenDepartment of Biomedical Engineering, Faculty of Applied Science, Ho Chi Minh City University of Technology (HCMUT), 268 Ly Thuong Kiet, District 10, Ho Chi Minh City, 700000, Vietnam. haunguyen85@hcmut.edu.vn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study addresses the growing importance of hand gesture recognition across diverse fields, such as industry, education, and healthcare, targeting the often-neglected needs of the deaf and dumb community. The primary objective is to improve communication between individuals, thereby enhancing the overall quality of life, particularly in the context of advanced healthcare. This paper presents a novel approach for real-time hand gesture recognition using bio-impedance techniques. The developed device, powered by a Raspberry Pi and connected to electrodes for impedance data acquisition, employs an impedance chip for data collection. To categorize hand gestures, Convolutional Neuron Network (CNN), XGBoost, and Random Forest were used. The model successfully recognized up to nine distinct gestures, achieving an average accuracy of 97.24% across ten subjects using a subject-dependent strategy, showcasing the efficacy of the bioimpedance-based system in hand gesture recognition. The promising results lay a foundation for future developments in nonverbal communication between humans and machines as it contributes to the advancement of technology for the benefit of individuals with hearing impairments, addressing a critical social need.

Indexed as

Electric ImpedanceGesturesHandAdultFemaleHumansMaleNeural Networks, ComputerPattern Recognition, AutomatedSoutheast Asian PeopleVietnamBioimpedanceDeep learningHand gesture recognition

Identifiers

PMID39738434
PMCPMC11686314

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.